Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout

التفاصيل البيبلوغرافية
العنوان: Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
المؤلفون: Aoki, Yumi, Attié, David, Behnke, Ties, Bellerive, Alain, Bezshyyko, Oleg, Sankar, Deb Bhattacharya, Bhattacharya, Purba, Bhattacharya, Sudeb, Chang, Yue, Colas, Paul, De Lentdecker, Gilles, Dehmelt, Klaus, Desch, Klaus, Diener, Ralf, Dixit, Madhu, Einhaus, Ulrich, Fedorchuk, Oleksiy, Fleck, Ivor, Fujii, Keisuke, Fusayasu, Takahiro, Ganjour, Serguei, Gros, Philippe, Hayman, Peter, Ikematsu, Katsumasa, Jönsson, Leif, Kaminski, Jochen, Kato, Yukihiro, Kleinwort, Claus, Martin, Peter Kluit, Kobayashi, Makoto, Krämer, Uwe, Lundberg, Björn, Lupberger, Michael, Majumdar, Nayana, Malek, Paul, Matsuda, Takeshi, Mjoernmark, Ulf, Mukhopadhyay, Supratik, Müller, Felix, Münnich, Astrid, Nakajima, Jurina, Narita, Shinya, Negishi, Kentaro, Ogawa, Tomohisa, Oskarsson, Anders, Österman, Lennart, Peterson, Daniel, Qi, Huirong, Riallot, Marc, Rosemann, Christoph, Roth, Stefan, Schade, Peter, Schaefer, Oliver, Settles, Ronald Dean, Shirazi, Amir Noori, Shoji, Aiko, Smirnova, Oxana, Sugiyama, Akira, Takahashi, Tohru, Timmermans, Jan, Titov, Maksym, Tsionou, Dimitra, Vauth, Annika, Watanabe, Takashi, Werthenbach, Ulrich, Wu, Mengqing, Yang, Yifan, Yonamine, Ryo, Yuan, Zhiyang, Yumino, Keita, Zhang, Fan
المصدر: Journal of Instrumentation, Volume 17, Number 11, P11027 -, November 2022
سنة النشر: 2022
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Instrumentation and Detectors
الوصف: A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
Comment: 29 pages, 30 figures, 6 tables. This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/17/11/P11027
نوع الوثيقة: Working Paper
DOI: 10.1088/1748-0221/17/11/P11027
URL الوصول: http://arxiv.org/abs/2205.12160
رقم الأكسشن: edsarx.2205.12160
قاعدة البيانات: arXiv
الوصف
DOI:10.1088/1748-0221/17/11/P11027