Automatic Segmentation of the Great Arteries for Computational Hemodynamic Assessment

التفاصيل البيبلوغرافية
العنوان: Automatic Segmentation of the Great Arteries for Computational Hemodynamic Assessment
المؤلفون: Montalt-Tordera, Javier, Pajaziti, Endrit, Jones, Rod, Sauvage, Emilie, Puranik, Rajesh, Singh, Aakansha Ajay Vir, Capelli, Claudio, Steeden, Jennifer, Schievano, Silvia, Muthurangu, Vivek
سنة النشر: 2022
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Medical Physics
الوصف: Background: Computational fluid dynamics (CFD) is increasingly used to assess blood flow conditions in patients with congenital heart disease (CHD). This requires patient-specific anatomy, usually obtained from segmented 3D cardiovascular magnetic resonance (CMR) images. However, segmentation is time-consuming and needs expert input. This study aims to develop and validate a machine learning (ML) method for segmentation of the aorta and pulmonary arteries (PAs) for CFD studies. Methods: 90 CHD patients were retrospectively selected for this study. 3D CMR images were manually segmented to obtain ground-truth (GT) background, aorta and PA labels. These were used to train and optimize a U-Net model. Segmentation performance was primarily evaluated using Dice score. CFD simulations were set up from GT and ML segmentations using a semi-automatic meshing and simulation pipeline. Pressure and velocity fields were computed, and a mean average percentage error (MAPE) was calculated for each vessel pair. A secondary observer (SO) segmented the test dataset to assess inter-observer variability. Friedman tests were used to compare segmentation metrics and flow field errors. Results: The model's Dice score (ML vs GT) was 0.945 for the aorta and 0.885 for the PAs. Differences with the inter-observer Dice score (SO vs GT) and ML vs SO Dice scores were not statistically significant for either aorta or PAs. The ML vs GT MAPEs for pressure and velocity in the aorta were 10.1% and 4.1% respectively, and for the PAs 14.6% and 6.3%, respectively. Inter-observer (SO vs GT) and ML vs SO pressure and velocity MAPEs were of a similar magnitude to ML vs GT. Conclusions: The proposed method can successfully segment the great vessels for CFD, with errors similar to inter-observer variability. This reduces the time and effort needed for CFD analysis, making it more attractive for routine clinical use.
Comment: 27 pages, 10 figures
نوع الوثيقة: Working Paper
URL الوصول: http://arxiv.org/abs/2209.06117
رقم الأكسشن: edsarx.2209.06117
قاعدة البيانات: arXiv