Gait Event Detection and Travel Distance Using Waist-Worn Accelerometers across a Range of Speeds: Automated Approach

التفاصيل البيبلوغرافية
العنوان: Gait Event Detection and Travel Distance Using Waist-Worn Accelerometers across a Range of Speeds: Automated Approach
المؤلفون: Ramli, Albara Ah, Liu, Xin, Berndt, Kelly, Chuah, Chen-Nee, Goude, Erica, Kaethler, Lynea B., Lopez, Amanda, Nicorici, Alina, Owens, Corey, Rodriguez, David, Wang, Jane, Aranki, Daniel, McDonald, Craig M., Henricson, Erik K.
المصدر: Sensors. 2024; 24(4):1155
سنة النشر: 2023
المجموعة: Computer Science
مصطلحات موضوعية: Electrical Engineering and Systems Science - Signal Processing, Computer Science - Artificial Intelligence, Computer Science - Machine Learning
الوصف: Estimation of temporospatial clinical features of gait (CFs), such as step count and length, step duration, step frequency, gait speed, and distance traveled, is an important component of community-based mobility evaluation using wearable accelerometers. However, accurate unsupervised computerized measurement of CFs of individuals with Duchenne muscular dystrophy (DMD) who have progressive loss of ambulatory mobility is difficult due to differences in patterns and magnitudes of acceleration across their range of attainable gait velocities. This paper proposes a novel calibration method. It aims to detect steps, estimate stride lengths, and determine travel distance. The approach involves a combination of clinical observation, machine-learning-based step detection, and regression-based stride length prediction. The method demonstrates high accuracy in children with DMD and typically developing controls (TDs) regardless of the participant's level of ability. Fifteen children with DMD and fifteen TDs underwent supervised clinical testing across a range of gait speeds using 10 m or 25 m run/walk (10 MRW, 25 MRW), 100 m run/walk (100 MRW), 6-min walk (6 MWT), and free-walk (FW) evaluations while wearing a mobile-phone-based accelerometer at the waist near the body's center of mass. Following calibration by a trained clinical evaluator, CFs were extracted from the accelerometer data using a multi-step machine-learning-based process and the results were compared to ground-truth observation data. Model predictions vs. observed values for step counts, distance traveled, and step length showed a strong correlation. Our study findings indicate that a single waist-worn accelerometer calibrated to an individual's stride characteristics using our methods accurately measures CFs and estimates travel distances across a common range of gait speeds in both DMD and TD peers.
نوع الوثيقة: Working Paper
DOI: 10.3390/s24041155
URL الوصول: http://arxiv.org/abs/2307.04866
رقم الأكسشن: edsarx.2307.04866
قاعدة البيانات: arXiv