Ultra-High precision Compton polarimetry at 2 GeV

التفاصيل البيبلوغرافية
العنوان: Ultra-High precision Compton polarimetry at 2 GeV
المؤلفون: Zec, A., Premathilake, S., Cornejo, J. C., Dalton, M. M., Gal, C., Gaskell, D., Gericke, M., Halilovic, I., Liu, H., Mammei, J., Michaels, R., Palatchi, C., Pan, J., Paschke, K. D., Quinn, B., Zhang, J.
المصدر: Phys. Rev. C 109, 024323 2024
سنة النشر: 2024
المجموعة: Nuclear Experiment
Physics (Other)
مصطلحات موضوعية: Physics - Instrumentation and Detectors, Nuclear Experiment
الوصف: We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest accuracy in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLAC Large Detector (SLD) Compton polarimeter. Such uncertainty reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID experiments.
نوع الوثيقة: Working Paper
DOI: 10.1103/PhysRevC.109.024323
URL الوصول: http://arxiv.org/abs/2402.16135
رقم الأكسشن: edsarx.2402.16135
قاعدة البيانات: arXiv
الوصف
DOI:10.1103/PhysRevC.109.024323