دورية أكاديمية

Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison

التفاصيل البيبلوغرافية
العنوان: Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
المؤلفون: Xin Wang, Fang Zhang, Dan Ma, Xiaolan Ye, Xiaojuan Zheng, Ruifang Ren, Nan Ren, Shizhu Bai
المصدر: Heliyon, Vol 10, Iss 10, Pp e31063- (2024)
بيانات النشر: Elsevier, 2024.
سنة النشر: 2024
المجموعة: LCC:Science (General)
LCC:Social sciences (General)
مصطلحات موضوعية: Science (General), Q1-390, Social sciences (General), H1-99
الوصف: Statement of problem: Intraoral scanners (IOSs) are widely used in dentistry, providing high accuracy in short-range scanning. Nevertheless, when scanning the full dental arch, it remains a challenge. Furthermore, there is a lack of studies reporting the differences in scan accuracy between dental arches with large-span mucosal areas and fully dentate casts or optimal IOS selection for different dental statuses. Purpose: This study aimed to evaluate the accuracy and scanning time of different IOSs for full dentate (FD) and partially edentulous (PE) casts with missing teeth in the #34–#44 range and to determine the IOSs with the optimal clinical adaptability and scanning accuracy for different complete-arch casts. Material and methods: Reference scans of two complete-arch (FD and PE) casts were obtained using a laboratory scanner (Ceramill Map 600). Subsequently, the same casts were scanned ten times each by seven IOSs (3Shape Trios 3, CS3600, Planmeca Emerald, iTero Element 5D, Medit i500, BAMBOO B1, and Shining Aoralscan 3), and the scanning time was recorded. The test data were superimposed on the reference scans for the selected areas, and three-dimensional deviations between the reference and test casts (trueness), and between test casts (precision) were determined using reverse engineering software (Geomagic Wrap). The dataset was analyzed using a two-factor analysis of variance with post-hoc Bonferroni tests. Results: Two-factor analysis of variance revealed significant differences in accuracy and scanning time for different casts (P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2405-8440
Relation: http://www.sciencedirect.com/science/article/pii/S2405844024070944; https://doaj.org/toc/2405-8440
DOI: 10.1016/j.heliyon.2024.e31063
URL الوصول: https://doaj.org/article/01a4f74cdf884b56893e166769aa850a
رقم الأكسشن: edsdoj.01a4f74cdf884b56893e166769aa850a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:24058440
DOI:10.1016/j.heliyon.2024.e31063