دورية أكاديمية
Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study
العنوان: | Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study |
---|---|
المؤلفون: | Buekers, Joren, Theunis, Jan, De Boever, Patrick, Vaes, Anouk W, Koopman, Maud, Janssen, Eefje VM, Wouters, Emiel FM, Spruit, Martijn A, Aerts, Jean-Marie |
المصدر: | JMIR mHealth and uHealth, Vol 7, Iss 6, p e12866 (2019) |
بيانات النشر: | JMIR Publications, 2019. |
سنة النشر: | 2019 |
المجموعة: | LCC:Information technology LCC:Public aspects of medicine |
مصطلحات موضوعية: | Information technology, T58.5-58.64, Public aspects of medicine, RA1-1270 |
الوصف: | BackgroundChronic obstructive pulmonary disease (COPD) patients can suffer from low blood oxygen concentrations. Peripheral blood oxygen saturation (SpO2), as assessed by pulse oximetry, is commonly measured during the day using a spot check, or continuously during one or two nights to estimate nocturnal desaturation. Sampling at this frequency may overlook natural fluctuations in SpO2. ObjectiveThis study used wearable finger pulse oximeters to continuously measure SpO2 during daily home routines of COPD patients and assess natural SpO2 fluctuations. MethodsA total of 20 COPD patients wore a WristOx2 pulse oximeter for 1 week to collect continuous SpO2 measurements. A SenseWear Armband simultaneously collected actigraphy measurements to provide contextual information. SpO2 time series were preprocessed and data quality was assessed afterward. Mean SpO2, SpO2 SD, and cumulative time spent with SpO2 below 90% (CT90) were calculated for every (1) day, (2) day in rest, and (3) night to assess SpO2 fluctuations. ResultsA high percentage of valid SpO2 data (daytime: 93.27%; nocturnal: 99.31%) could be obtained during a 7-day monitoring period, except during moderate-to-vigorous physical activity (MVPA) (67.86%). Mean nocturnal SpO2 (89.9%, SD 3.4) was lower than mean daytime SpO2 in rest (92.1%, SD 2.9; P |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2291-5222 |
Relation: | https://mhealth.jmir.org/2019/6/e12866/; https://doaj.org/toc/2291-5222 |
DOI: | 10.2196/12866 |
URL الوصول: | https://doaj.org/article/048a517874804b24afb70b2d07112c6b |
رقم الأكسشن: | edsdoj.048a517874804b24afb70b2d07112c6b |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 22915222 |
---|---|
DOI: | 10.2196/12866 |