Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study

التفاصيل البيبلوغرافية
العنوان: Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study
المؤلفون: Buekers, Joren, Theunis, Jan, De Boever, Patrick, Vaes, Anouk W, Koopman, Maud, Janssen, Eefje VM, Wouters, Emiel FM, Spruit, Martijn A, Aerts, Jean-Marie
المصدر: JMIR mHealth and uHealth, Vol 7, Iss 6, p e12866 (2019)
بيانات النشر: JMIR Publications, 2019.
سنة النشر: 2019
المجموعة: LCC:Information technology
LCC:Public aspects of medicine
مصطلحات موضوعية: Information technology, T58.5-58.64, Public aspects of medicine, RA1-1270
الوصف: BackgroundChronic obstructive pulmonary disease (COPD) patients can suffer from low blood oxygen concentrations. Peripheral blood oxygen saturation (SpO2), as assessed by pulse oximetry, is commonly measured during the day using a spot check, or continuously during one or two nights to estimate nocturnal desaturation. Sampling at this frequency may overlook natural fluctuations in SpO2. ObjectiveThis study used wearable finger pulse oximeters to continuously measure SpO2 during daily home routines of COPD patients and assess natural SpO2 fluctuations. MethodsA total of 20 COPD patients wore a WristOx2 pulse oximeter for 1 week to collect continuous SpO2 measurements. A SenseWear Armband simultaneously collected actigraphy measurements to provide contextual information. SpO2 time series were preprocessed and data quality was assessed afterward. Mean SpO2, SpO2 SD, and cumulative time spent with SpO2 below 90% (CT90) were calculated for every (1) day, (2) day in rest, and (3) night to assess SpO2 fluctuations. ResultsA high percentage of valid SpO2 data (daytime: 93.27%; nocturnal: 99.31%) could be obtained during a 7-day monitoring period, except during moderate-to-vigorous physical activity (MVPA) (67.86%). Mean nocturnal SpO2 (89.9%, SD 3.4) was lower than mean daytime SpO2 in rest (92.1%, SD 2.9; P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2291-5222
Relation: https://mhealth.jmir.org/2019/6/e12866/; https://doaj.org/toc/2291-5222
DOI: 10.2196/12866
URL الوصول: https://doaj.org/article/048a517874804b24afb70b2d07112c6b
رقم الأكسشن: edsdoj.048a517874804b24afb70b2d07112c6b
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22915222
DOI:10.2196/12866