دورية أكاديمية

Comparative analysis of canalicular diameter in opened or closed eyes by ultrasound biomicroscope

التفاصيل البيبلوغرافية
العنوان: Comparative analysis of canalicular diameter in opened or closed eyes by ultrasound biomicroscope
المؤلفون: Li-Ping Xu, Hao-Jie Liu, Ming Zhou, Jian Shen
المصدر: Guoji Yanke Zazhi, Vol 16, Iss 4, Pp 773-775 (2016)
بيانات النشر: Press of International Journal of Ophthalmology (IJO PRESS), 2016.
سنة النشر: 2016
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: canaliculus, ultrasound biomicroscope, canalicular diameter, opened eye, closed eye, Ophthalmology, RE1-994
الوصف: AIM:To compare the canalicular diameter when eyes opened and closed using ultrasound biomicroscope. METHODS:Twenty volunteers(20 eyes)with nasolacrimal duct obstruction were included. The lower canaliculus of one eye in every volunteer was detected and measured with ultrasound biomicroscope when eyes opened and closed. Before measurements sodium hyaluronate was injected through the upper lacrimal puncta until it overflowed from the lower lacrimal puncta. The length of the vertical canaliculus, anteroposterior diameter of the vertical canaliculus at the proximal, middle, distal, anteroposterior diameter and vertical diameter of the horizontal canaliculus at the proximal, middle, distal were measured. According to elliptical area formula S=πab(a =1/2 anteroposterior diameter,b=1/2 vertical diameter), transverse area of the horizontal canaliculus at the distal, middle and proximal were calculated. The differences of measurement when eyes opened and closed were compared by paired t test. RESULTS:When eyes opened and closed, the length of vertical canaliculus of inferior canaliculus were respectively 2.56±0.33 and 2.76±0.34mm; anteroposterior diameters at the distal part were respectively 0.29±0.04 and 0.32±0.04mm; those at the middle were respectively 0.32±0.03 and 0.35±0.04mm; those at the proximal were respectively 0.38±0.02 and 0.40±0.04mm and those differences between opened and closed eyes were statistically significant(t=-5.346, -5.12, -4.94, -4.682; P2; those at the middle were respectively 0.67±0.04 and 0.75±0.08mm2; those at the proximal were respectively 0.51±0.10 and 0.56±0.15mm2 and those differences between opened and closed eyes were statistically significant(t=-7.453, -6.73, -6.43; PCONCLUSION:Compared with the opened eyes, the vertical length of lower canaliculus become shorter, the anteroposterior diameter of vertical canaliculus and transverse areas of horizontal canaliculus become smaller.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1672-5123
Relation: http://ies.ijo.cn/cn_publish/2016/4/201604050.pdf; https://doaj.org/toc/1672-5123
DOI: 10.3980/j.issn.1672-5123.2016.4.50
URL الوصول: https://doaj.org/article/d05e4bb316bf4746bc61de28267f2731
رقم الأكسشن: edsdoj.05e4bb316bf4746bc61de28267f2731
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16725123
DOI:10.3980/j.issn.1672-5123.2016.4.50