Randomized Trial Comparing Prediction Accuracy of Two Swept Source Optical Coherence Tomography Biometers

التفاصيل البيبلوغرافية
العنوان: Randomized Trial Comparing Prediction Accuracy of Two Swept Source Optical Coherence Tomography Biometers
المؤلفون: Multack S, Plummer N, Smits G, Hall B
المصدر: Clinical Ophthalmology, Vol Volume 17, Pp 2423-2428 (2023)
بيانات النشر: Dove Medical Press, 2023.
سنة النشر: 2023
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: argos, iolmaster 700, swept source optical coherence tomography, ss-oct, cataract surgery, biometry, Ophthalmology, RE1-994
الوصف: Sam Multack,1 Nellie Plummer,1 Gerard Smits,2 Brad Hall3 1Multack Eye Care, Frankfort, IL, USA; 2CSC, Inc., Santa Barbara, CA, USA; 3Sengi, Penniac, NB, CanadaCorrespondence: Sam Multack, Multack Eye Care, 22200 Wolf Road, Frankfort, IL, 60423, USA, Tel +1 815-889-3333, Email smultack@mecvision.comPurpose: To compare the prediction accuracy of the Argos biometer using standard keratometry to the prediction accuracy of the IOLMaster 700 biometer using Total Keratometry.Methods: This was a randomized, prospective, single surgeon study of 80 right eyes of 80 patients that had preoperative biometry with both the Argos and IOLMaster 700 devices, followed by cataract surgery and intraocular lens (IOL) implantation. Prediction errors (directional and absolute) for each device were determined from the 1 month postoperative manifest refraction.Results: The directional prediction error was 0.07 ± 0.32 D for the Argos and 0.08 ± 0.34 D for the IOLMaster 700. The mean of the difference in prediction error (directional) was 0.02 D, which was not statistically significant (p > 0.05). The absolute prediction error was 0.21 ± 0.25 D for the Argos and 0.25 ± 0.24 D for the IOLMaster 700. The mean of the difference in absolute prediction error was 0.04 D, which was statistically significant (p < 0.004) but not clinically significant. The percentage of eyes with absolute prediction error ≤ 0.5 D was 91% (73 eyes) for the Argos and 88% (70 eyes) for the IOLMaster 700. This difference was not statistically significant.Conclusion: The prediction accuracies were similar between the Argos and IOLMaster 700 in eyes with normal axial length. There was a significant difference in mean absolute prediction error between devices; however, this was not clinically meaningful.Keywords: Argos, IOLMaster 700, swept source optical coherence tomography, SS-OCT, cataract surgery, biometry
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1177-5483
Relation: https://www.dovepress.com/randomized-trial-comparing-prediction-accuracy-of-two-swept-source-opt-peer-reviewed-fulltext-article-OPTH; https://doaj.org/toc/1177-5483
URL الوصول: https://doaj.org/article/e07a7797ef7046e08ef684d40b24f9c6
رقم الأكسشن: edsdoj.07a7797ef7046e08ef684d40b24f9c6
قاعدة البيانات: Directory of Open Access Journals