دورية أكاديمية

Comparison of Sprotte and Quincke Spinal Needles on the Frequency of Spinal Anesthesia Failure in Patients undergoing Cesarean Delivery

التفاصيل البيبلوغرافية
العنوان: Comparison of Sprotte and Quincke Spinal Needles on the Frequency of Spinal Anesthesia Failure in Patients undergoing Cesarean Delivery
المؤلفون: Simin Atashkhoei, Eissa Bilehjani, Fariba Nassiri Milani, Sajjad Pourasghary, Solmaz Fakhari
المصدر: Journal of Evidence-Based Care, Vol 12, Iss 2, Pp 41-50 (2022)
بيانات النشر: Mashhad University of Medical Sciences, 2022.
سنة النشر: 2022
المجموعة: LCC:Nursing
LCC:Gynecology and obstetrics
مصطلحات موضوعية: cesarean delivery, spinal anesthesia, failure, sprotte, quincke, Nursing, RT1-120, Gynecology and obstetrics, RG1-991
الوصف: Introduction: The aim of the present study was to compare Sprotte and Quincke spinal needles on the frequency of spinal anesthesia failure in patients undergoing cesarean delivery.Materials and Methods: In this randomized and double-blind clinical trial, 100 pregnant women in ASA class I or II, term and single pregnancies who were candidates for elective cesarean section with spinal anesthesia were studied. In patients of the study group (n=50), spinal anesthesia was performed using Sprotte spinal needle 25G and in patients of the control group (n=50) with Quincke's spinal needle 25G. The frequency of spinal anesthesia failure was recorded as complete and partial failure.Results: In the study group, one patient of incomplete failure two patients with complete failure; and in the control group, 2 patients of incomplete failure and 3 patients of complete failure were observed, which was not a statistically significant difference between the two study groups (p=0.749). Only 3 patients of the control group require repeat spinal block. The frequency of sensory (p=0.002) and motor (p=0.001) block for surgery was significantly higher in the study group than in the control group. The Post-Dural puncture headache (PDPH) was significantly higher in the control group (14% vs. 0%; p=0.006).Conclusion: The frequency of spinal anesthesia failure and post-Dural puncture headache (PDPH) using Sprotte spinal needle was lower than in Quincke needle in patients with spinal anesthesia for cesarean delivery.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: Persian
تدمد: 2008-2487
2008-370X
Relation: https://ebcj.mums.ac.ir/article_20247_58db323330876cc224cecdfb99ceaa28.pdf; https://doaj.org/toc/2008-2487; https://doaj.org/toc/2008-370X
DOI: 10.22038/ebcj.2022.63511.2648
URL الوصول: https://doaj.org/article/07d3ff015d3c4998b6d46bb3b6097770
رقم الأكسشن: edsdoj.07d3ff015d3c4998b6d46bb3b6097770
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20082487
2008370X
DOI:10.22038/ebcj.2022.63511.2648