دورية أكاديمية

Diagnosis of Sleep Apnoea Using a Mandibular Monitor and Machine Learning Analysis: One-Night Agreement Compared to in-Home Polysomnography

التفاصيل البيبلوغرافية
العنوان: Diagnosis of Sleep Apnoea Using a Mandibular Monitor and Machine Learning Analysis: One-Night Agreement Compared to in-Home Polysomnography
المؤلفون: Julia L. Kelly, Raoua Ben Messaoud, Marie Joyeux-Faure, Robin Terrail, Renaud Tamisier, Jean-Benoît Martinot, Nhat-Nam Le-Dong, Mary J. Morrell, Jean-Louis Pépin
المصدر: Frontiers in Neuroscience, Vol 16 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: sleep apnoea, polysomnography, mandibular monitor, in-home diagnosis, one-night agreement, performance, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: BackgroundThe capacity to diagnose obstructive sleep apnoea (OSA) must be expanded to meet an estimated disease burden of nearly one billion people worldwide. Validated alternatives to the gold standard polysomnography (PSG) will improve access to testing and treatment. This study aimed to evaluate the diagnosis of OSA, using measurements of mandibular movement (MM) combined with automated machine learning analysis, compared to in-home PSG.Methods40 suspected OSA patients underwent single overnight in-home sleep testing with PSG (Nox A1, ResMed, Australia) and simultaneous MM monitoring (Sunrise, Sunrise SA, Belgium). PSG recordings were manually analysed by two expert sleep centres (Grenoble and London); MM analysis was automated. The Obstructive Respiratory Disturbance Index calculated from the MM monitoring (MM-ORDI) was compared to the PSG (PSG-ORDI) using intraclass correlation coefficient and Bland-Altman analysis. Receiver operating characteristic curves (ROC) were constructed to optimise the diagnostic performance of the MM monitor at different PSG-ORDI thresholds (5, 15, and 30 events/hour).Results31 patients were included in the analysis (58% men; mean (SD) age: 48 (15) years; BMI: 30.4 (7.6) kg/m2). Good agreement was observed between MM-ORDI and PSG-ORDI (median bias 0.00; 95% CI −23.25 to + 9.73 events/hour). However, for 15 patients with no or mild OSA, MM monitoring overestimated disease severity (PSG-ORDI < 5: MM-ORDI mean overestimation + 5.58 (95% CI + 2.03 to + 7.46) events/hour; PSG-ORDI > 5–15: MM-ORDI overestimation + 3.70 (95% CI −0.53 to + 18.32) events/hour). In 16 patients with moderate-severe OSA (n = 9 with PSG-ORDI 15–30 events/h and n = 7 with a PSG-ORD > 30 events/h), there was an underestimation (PSG-ORDI > 15: MM-ORDI underestimation −8.70 (95% CI −28.46 to + 4.01) events/hour). ROC optimal cut-off values for PSG-ORDI thresholds of 5, 15, 30 events/hour were: 9.53, 12.65 and 24.81 events/hour, respectively. These cut-off values yielded a sensitivity of 88, 100 and 79%, and a specificity of 100, 75, 96%. The positive predictive values were: 100, 80, 95% and the negative predictive values 89, 100, 82%, respectively.ConclusionThe diagnosis of OSA, using MM with machine learning analysis, is comparable to manually scored in-home PSG. Therefore, this novel monitor could be a convenient diagnostic tool that can easily be used in the patients’ own home.Clinical Trial Registrationhttps://clinicaltrials.gov, identifier NCT04262557
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1662-453X
Relation: https://www.frontiersin.org/articles/10.3389/fnins.2022.726880/full; https://doaj.org/toc/1662-453X
DOI: 10.3389/fnins.2022.726880
URL الوصول: https://doaj.org/article/0854ebe4051245f8b171623ff8005dbf
رقم الأكسشن: edsdoj.0854ebe4051245f8b171623ff8005dbf
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1662453X
DOI:10.3389/fnins.2022.726880