Clinical Utility of a Fully Automated Microsatellite Instability Test with Minimal Hands-on Time

التفاصيل البيبلوغرافية
العنوان: Clinical Utility of a Fully Automated Microsatellite Instability Test with Minimal Hands-on Time
المؤلفون: Miseon Lee, Sung-Min Chun, Chang Ohk Sung, Sun Y. Kim, Tae W. Kim, Se Jin Jang, Jihun Kim
المصدر: Journal of Pathology and Translational Medicine, Vol 53, Iss 6, Pp 386-392 (2019)
بيانات النشر: Korean Society of Pathologists & the Korean Society for Cytopathology, 2019.
سنة النشر: 2019
المجموعة: LCC:Pathology
مصطلحات موضوعية: microsatellite instability, polymerase chain reaction, idylla msi test, diagnostic performance, tumor purity, Pathology, RB1-214
الوصف: Background Microsatellite instability (MSI) analysis is becoming increasingly important in many types of tumor including colorectal cancer (CRC). The commonly used MSI tests are either time-consuming or labor-intensive. A fully automated MSI test, the Idylla MSI assay, has recently been introduced. However, its diagnostic performance has not been extensively validated in clinical CRC samples. Methods We evaluated 133 samples whose MSI status had been rigorously validated by standard polymerase chain reaction (PCR), clinical next-generation sequencing (NGS) cancer panel test, or both. We evaluated the diagnostic performance of the Idylla MSI assay in terms of sensitivity, specificity, and positive and negative predictive values, as well as various sample requirements, such as minimum tumor purity and the quality of paraffin blocks. Results Compared with the gold standard results confirmed through both PCR MSI test and NGS, the Idylla MSI assay showed 99.05% accuracy (104/105), 100% sensitivity (11/11), 98.94% specificity (93/94), 91.67% positive predictive value (11/12), and 100% negative predictive value (93/93). In addition, the Idylla MSI assay did not require macro-dissection in most samples and reliably detected MSI-high in samples with approximately 10% tumor purity. The total turnaround time was about 150 minutes and the hands-on time was less than 2 minutes. Conclusions The Idylla MSI assay shows good diagnostic performance that is sufficient for its implementation in the clinic to determine the MSI status of at least the CRC samples. In addition, the fully automated procedure requires only a few slices of formalin-fixed paraffin-embedded tissue and might greatly save time and labor.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Korean
تدمد: 2383-7837
2383-7845
Relation: http://www.jpatholtm.org/upload/pdf/jptm-2019-09-25.pdf; https://doaj.org/toc/2383-7837; https://doaj.org/toc/2383-7845
DOI: 10.4132/jptm.2019.09.25
URL الوصول: https://doaj.org/article/a087cd830413479eb9f33b758c0e9db6
رقم الأكسشن: edsdoj.087cd830413479eb9f33b758c0e9db6
قاعدة البيانات: Directory of Open Access Journals