دورية أكاديمية

Comparison of Positive End-Expiratory Pressure versus Tidal Volume-Induced Ventilator-Driven Alveolar Recruitment Maneuver in Robotic Prostatectomy: A Randomized Controlled Study

التفاصيل البيبلوغرافية
العنوان: Comparison of Positive End-Expiratory Pressure versus Tidal Volume-Induced Ventilator-Driven Alveolar Recruitment Maneuver in Robotic Prostatectomy: A Randomized Controlled Study
المؤلفون: Kangha Jung, Sojin Kim, Byung Jun Kim, MiHye Park
المصدر: Journal of Clinical Medicine, Vol 10, Iss 17, p 3921 (2021)
بيانات النشر: MDPI AG, 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine
مصطلحات موضوعية: alveolar recruitment maneuver, atelectasis, electrical impedance tomography, end-expiratory lung impedance, laparoscopy, lung compliance, Medicine
الوصف: Background: We evaluated the pulmonary effects of two ventilator-driven alveolar recruitment maneuver (ARM) methods during laparoscopic surgery. Methods: Sixty-four patients undergoing robotic prostatectomy were randomized into two groups: incrementally increasing positive end-expiratory pressure in a stepwise manner (PEEP group) versus tidal volume (VT group). We performed each ARM after induction of anesthesia in the supine position (T1), after pneumoperitoneum in the Trendelenburg position (T2), and after peritoneum desufflation in the supine position (T3). The primary outcome was change in end-expiratory lung impedance (EELI) before and 5 min after ARM at T3, measured by electrical impedance tomography. Results: The PEEP group showed significantly higher increasing EELI 5 min after ARM than the VT group at T1 and T3 (median [IQR] 460 [180,800] vs. 200 [80,315], p = 0.002 and 280 [170,420] vs. 95 [55,175], p = 0.004, respectively; PEEP group vs. VT group). The PEEP group showed significantly higher lung compliance and lower driving pressure at T1 and T3. However, there was no significant difference in EELI change, lung compliance, or driving pressure after ARM at T2. Conclusions: The ventilator-driven ARM by the increasing PEEP method led to greater improvements in lung compliance at the end of laparoscopic surgery than the increasing VT method.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
Relation: https://www.mdpi.com/2077-0383/10/17/3921; https://doaj.org/toc/2077-0383
DOI: 10.3390/jcm10173921
URL الوصول: https://doaj.org/article/09953d14b51243419afcdb5f6e3487b5
رقم الأكسشن: edsdoj.09953d14b51243419afcdb5f6e3487b5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383