دورية أكاديمية

Decellularized Porcine Conjunctiva in Treating Severe Symblepharon

التفاصيل البيبلوغرافية
العنوان: Decellularized Porcine Conjunctiva in Treating Severe Symblepharon
المؤلفون: Fengmei Shan, Xueying Feng, Jie Li, Sha Yang, Fuhua Wang, Weiyun Shi, Long Zhao, Qingjun Zhou
المصدر: Journal of Functional Biomaterials, Vol 14, Iss 6, p 318 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Biotechnology
LCC:Medicine (General)
مصطلحات موضوعية: decellularized extracellular matrix, symblepharon, oral mucosal transplantation, conjunctival reconstruction, Biotechnology, TP248.13-248.65, Medicine (General), R5-920
الوصف: This prospective study aimed to evaluate the effectiveness of decellularized porcine conjunctiva (DPC) in the management of severe symblepharon. Sixteen patients with severe symblepharon were enrolled in this study. After symblepharon lysis and Mitomycin C (MMC) application, tarsus defects were covered with residual autologous conjunctiva (AC), autologous oral mucosa (AOM), or DPC throughout the fornix, and DPC was used for all the exposed sclera. The outcomes were classified as complete success, partial success, or failure. Six symblepharon patients had chemical burns and ten had thermal burns. Tarsus defects were covered with DPC, AC, and AOM in two, three, and eleven cases, respectively. After an average follow-up of 20.0 ± 6 months, the anatomical outcomes observed were complete successes in twelve (three with AC+DPC, four with AC+AOM+DPC, and five with AOM+DPC) (75%) cases, partial successes in three (one with AOM+DPC and two with DPC+DPC) (18.75%) cases, and failure in one (with AOM+DPC) (6.25%) case. Before surgery, the depth of the narrowest part of the conjunctival sac was 0.59 ± 0.76 mm (range, 0–2 mm), tear fluid quantity (Schirmer II tests) was 12.5 ± 2.26 mm (range, 10–16 mm), and the distance of the eye rotation toward the opposite direction of the symblepharon was 3.75 ± 1.39 mm (range, 2–7 mm). The fornix depths increased to 7.53 ± 1.64 mm (range, 3–9 mm), eye movement was significantly improved, and the distance of eye movement reaching 6.56 ± 1.24 mm (range, 4–8 mm) 1 month after the operation; the postoperative Schirmer II test (12.06 ± 2.90 mm, range, 6–17 mm) was similar to that before surgery. Goblet cells were finally found in fifteen patients by conjunctival impression cytology in the transplantation area of DPC, except for one patient who failed. DPC could be considered an alternative for ocular surface reconstruction of severe symblepharon. Covering tarsal defects with autologous mucosa is necessary for extensive reconstruction of the ocular surface.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-4983
Relation: https://www.mdpi.com/2079-4983/14/6/318; https://doaj.org/toc/2079-4983
DOI: 10.3390/jfb14060318
URL الوصول: https://doaj.org/article/e0b716c59ec74010aa77e2e3eccb596a
رقم الأكسشن: edsdoj.0b716c59ec74010aa77e2e3eccb596a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20794983
DOI:10.3390/jfb14060318