دورية أكاديمية

A systematic review and meta-analysis of the clinical performance of implant-supported overdentures retained by CAD-CAM bars

التفاصيل البيبلوغرافية
العنوان: A systematic review and meta-analysis of the clinical performance of implant-supported overdentures retained by CAD-CAM bars
المؤلفون: Ana Paula Chappuis-Chocano, Helena Sandrini Venante, Rodrigo Moreira Bringel da Costa, Mariana Domingues Pordeus, Oscar Oswaldo Marcillo-Toala, Joel Ferreira Santiago Junior, Vinícius Carvalho Porto
المصدر: Journal of Applied Oral Science, Vol 31 (2023)
بيانات النشر: University of São Paulo, 2023.
سنة النشر: 2023
المجموعة: LCC:Dentistry
مصطلحات موضوعية: Denture, Overlay, Computer-Aided Design, Survival rate, Patient satisfaction, Oral Health, Dentistry, RK1-715
الوصف: Abstract Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars. Objective: To evaluate the performance of IODs involving CAD-CAM bars. Methodology: A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: “How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?” The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI). Results: Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies. Conclusion: Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1678-7765
1678-7757
52484173
Relation: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572023000100803&tlng=en; https://doaj.org/toc/1678-7765
DOI: 10.1590/1678-7757-2023-0054
URL الوصول: https://doaj.org/article/0d3e4f7f52484173aaf0098531f3f540
رقم الأكسشن: edsdoj.0d3e4f7f52484173aaf0098531f3f540
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16787765
16787757
52484173
DOI:10.1590/1678-7757-2023-0054