دورية أكاديمية

Association Between Corneal Changes and Retinal Oximetry in Diabetes Mellitus

التفاصيل البيبلوغرافية
العنوان: Association Between Corneal Changes and Retinal Oximetry in Diabetes Mellitus
المؤلفون: Ramm L, Spoerl E, Terai N, Herber R, Pillunat LE
المصدر: Clinical Ophthalmology, Vol Volume 18, Pp 1235-1243 (2024)
بيانات النشر: Dove Medical Press, 2024.
سنة النشر: 2024
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: diabetes mellitus, retinal oximetry, corneal optical densitometry, pachymetry, retinal vessel analyzer, pentacam hr, Ophthalmology, RE1-994
الوصف: Lisa Ramm, Eberhard Spoerl, Naim Terai, Robert Herber, Lutz E Pillunat Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Dresden, 01307, GermanyCorrespondence: Lisa Ramm, Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr 74, Dresden, 01307, Germany, Tel +49 351 458 3381, Fax +49 351 458 4335, Email lisa.ramm@uniklinikum-dresden.dePurpose: Diabetes mellitus (DM) causes different corneal changes that are associated with the severity of diabetic retinopathy. To identify the pathophysiological reasons for this, corneal tomography and optical densitometry (COD) were combined with retinal oximetry.Methods: Patients with DM and healthy subjects were included in this pilot study. Spatially resolved corneal thickness and COD were assessed using the Pentacam HR (Oculus). The pachymetry difference (PACDiff) was calculated as an indicator of an increase in the peripheral corneal thickness. Oxygen saturation (SO2) of the retinal vessels was measured using the Retinal Vessel Analyzer (Imedos Systems UG). Subsequently, the associations between corneal and retinal parameters were analyzed.Results: Data from 30 patients with DM were compared with those from 30 age-matched healthy subjects. In DM, arterial (P = 0.048) and venous (P < 0.001) SO2 levels were increased, and arteriovenous SO2 difference was decreased (P < 0.001). In patients, PACDiff was higher than that in healthy subjects (P < 0.05), indicating a stronger increase in peripheral corneal thickness. The COD was reduced in DM (P = 0.004). The PACDiff of concentric rings with a diameter of 4 mm (r = − 0.404; P = 0.033) to 8 mm (r = − 0.522; P = 0.004) was inversely correlated with the arteriovenous SO2 difference. Furthermore, PACDiff 4 mm was negatively associated with arterial SO2 (r = − 0.389; P = 0.041), and the COD of the peripheral corneal areas correlated positive with arterial SO2 (COD total 10– 12 mm: r = 0.408; P = 0.025).Conclusion: These associations might indicate a common pathogenesis of corneal and retinal changes in DM, which could be caused by reduced oxygen supply, mitochondrial dysfunction, oxidative stress, and cytokine effects.Plain Language Summary: Retinal changes are particularly important for ophthalmologists in the management of diabetes mellitus. These are primarily consequences of diabetic vascular changes that can lead to a lack of oxygen. However, there is also evidence of significant changes in the cornea of patients with diabetes. In the present study, the associations between changes in corneal thickness profile, optical density of the cornea, and oxygen saturation of retinal vessels in diabetes mellitus were demonstrated for the first time. Therefore, this study could contribute to clarifying the possible causes of corneal changes in patients with diabetes.Keywords: diabetes mellitus, retinal oximetry, corneal optical densitometry, pachymetry, retinal vessel analyzer, pentacam HR
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1177-5483
Relation: https://www.dovepress.com/association-between-corneal-changes-and-retinal-oximetry-in-diabetes-m-peer-reviewed-fulltext-article-OPTH; https://doaj.org/toc/1177-5483
URL الوصول: https://doaj.org/article/c0decb5350324f769d29f76929301b8e
رقم الأكسشن: edsdoj.0decb5350324f769d29f76929301b8e
قاعدة البيانات: Directory of Open Access Journals