دورية أكاديمية

Comparative evaluation of use of a diode laser and electrode application with and without two dentinal tubule occluding agents in the management of dentinal hypersensitivity – A clinical study

التفاصيل البيبلوغرافية
العنوان: Comparative evaluation of use of a diode laser and electrode application with and without two dentinal tubule occluding agents in the management of dentinal hypersensitivity – A clinical study
المؤلفون: Chitra Laxmikant Patil, Dilip Ganpat Pol, Rajesh Prabhakar Gaikwad
المصدر: Journal of Indian Society of Periodontology, Vol 24, Iss 6, Pp 535-540 (2020)
بيانات النشر: Wolters Kluwer Medknow Publications, 2020.
سنة النشر: 2020
المجموعة: LCC:Dentistry
مصطلحات موضوعية: dentinal hypersensitivity, diode laser, electrosurgical unit, hydroxyapatite, strontium chloride, verbal rating scale, visual analog scale, Dentistry, RK1-715
الوصف: Background: Dentinal hypersensitivity (DH) is common problem in dentistry. Traditional agents along with alternative therapies have been researched. Aim: To study the efficacy of a diode laser (DL) and electrode application with and without hydroxyapatite (HAP) and strontium chloride (SrCl2) powder. Materials and Methods: 60 Patients with mild cervical abrasion in at least two quadrant with two teeth per quadrant were selected and randomly divided into four groups: (i) Group 1– DL versus DL with HAP (ii) Group 2 – electrode application versus electrode application with HAP (iii) Group 3 - DL versus DL with SrCl2 (iv) Group 4 - electrode application versus electrode application with SrCl2 and were subjected to tactile stimulus and air blast test and scores were recorded on verbal rating scale (VRS) and visual analogues scale (VAS) at different time for 3 months. The data was statistically evaluated by one way ANOVA and paired t test. Results: In group 1 and 3, DL alone had a short term reduction of hypersensitivity (P = 0.001). Synergistic effect of DL and HAP (group 1) showed a prolonged reduction on both scales (P < 0.001) whereas the additive effect of SrCl2 with DL (group 3) showed statistically significant reduction on both scales at all time (p< 0.001). In group 2 there is insignificant difference on both scales at all time (P > 0.05) however group 4 showed significant reduction only in VAS score (p>0.05). Conclusion: DL alone had a short lived effect however with adjunctive sustained results were obtained whereas electrode application was neither beneficial nor did cause any adverse effect.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0972-124X
Relation: http://www.jisponline.com/article.asp?issn=0972-124X;year=2020;volume=24;issue=6;spage=535;epage=540;aulast=Patil; https://doaj.org/toc/0972-124X
DOI: 10.4103/jisp.jisp_523_19
URL الوصول: https://doaj.org/article/1314e4032e704607bcb09e8947b91b0a
رقم الأكسشن: edsdoj.1314e4032e704607bcb09e8947b91b0a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:0972124X
DOI:10.4103/jisp.jisp_523_19