دورية أكاديمية

Estimation of physiological exercise thresholds based on dynamical correlation properties of heart rate variability

التفاصيل البيبلوغرافية
العنوان: Estimation of physiological exercise thresholds based on dynamical correlation properties of heart rate variability
المؤلفون: Matias Kanniainen, Teemu Pukkila, Joonas Kuisma, Matti Molkkari, Kimmo Lajunen, Esa Räsänen
المصدر: Frontiers in Physiology, Vol 14 (2023)
بيانات النشر: Frontiers Media S.A., 2023.
سنة النشر: 2023
المجموعة: LCC:Physiology
مصطلحات موضوعية: heart rate variability, time series analysis, detrended fluctuation analysis, aerobic threshold, anaerobic threshold, wearable health technology, Physiology, QP1-981
الوصف: Aerobic and anaerobic thresholds of the three-zone exercise model are often used to evaluate the exercise intensity and optimize the training load. Conventionally, these thresholds are derived from the respiratory gas exchange or blood lactate concentration measurements. Here, we introduce and validate a computational method based on the RR interval (RRI) dynamics of the heart rate (HR) measurement, which enables a simple, yet reasonably accurate estimation of both metabolic thresholds. The method utilizes a newly developed dynamical detrended fluctuation analysis (DDFA) to assess the real-time changes in the dynamical correlations of the RR intervals during exercise. The training intensity is shown to be in direct correspondence with the time- and scale-dependent changes in the DDFA scaling exponent. These changes are further used in the definition of an individual measure to estimate the aerobic and anaerobic threshold. The results for 15 volunteers who participated in a cyclo-ergometer test are compared to the benchmark lactate thresholds, as well as to the ventilatory threshods and alternative HR-based estimates based on the maximal HR and the conventional detrended fluctuation analysis (DFA). Our method provides the best overall agreement with the lactate thresholds and provides a promising, cost-effective alternative to conventional protocols, which could be easily integrated in wearable devices. However, detailed statistical analysis reveals the particular strengths and weaknessess of each method with respect to the agreement and consistency with the thresholds—thus underlining the need for further studies with more data.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-042X
Relation: https://www.frontiersin.org/articles/10.3389/fphys.2023.1299104/full; https://doaj.org/toc/1664-042X
DOI: 10.3389/fphys.2023.1299104
URL الوصول: https://doaj.org/article/d16f11efb3dd4a05946d8b0fbf0a0281
رقم الأكسشن: edsdoj.16f11efb3dd4a05946d8b0fbf0a0281
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1664042X
DOI:10.3389/fphys.2023.1299104