دورية أكاديمية

Detection of unwarranted CT radiation exposure from patient and imaging protocol meta-data using regularized regression

التفاصيل البيبلوغرافية
العنوان: Detection of unwarranted CT radiation exposure from patient and imaging protocol meta-data using regularized regression
المؤلفون: Ruidi Chen, Ioannis Ch. Paschalidis, Hiroto Hatabu, Vladimir I. Valtchinov, Jenifer Siegelman
المصدر: European Journal of Radiology Open, Vol 6, Iss , Pp 206-211 (2019)
بيانات النشر: Elsevier, 2019.
سنة النشر: 2019
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Background: Variability in radiation exposure from CT scans can be appropriate and driven by patient features such as body habitus. Quantitative analysis may be performed to discover instances of unwarranted radiation exposure and to reduce the probability of such occurrences in future patient visits. No universal process to perform identification of outliers is widely available, and access to expertise and resources is variable. Objective: The goal of this study is to develop an automated outlier detection procedure to identify all scans with an unanticipated high radiation exposure, given the characteristics of the patient and the type of the exam. Materials and methods: This Institutional Review Board-approved retrospective cohort study was conducted from June 30, 2012 - December 31, 2013 in a quaternary academic medical center. The de-identified dataset contained 28 fields for 189,959 CT exams. We applied the variable selection method Least Absolute Shrinkage and Selection Operator (LASSO) to select important variables for predicting CT radiation dose. We then employed a regression approach that is robust to outliers, to learn from data a predictive model of CT radiation doses given important variables identified by LASSO. Patient visits whose predicted radiation dose was statistically different from the radiation dose actually received were identified as outliers. Results: Our methodology identified 1% of CT exams as outliers. The top-5 predictors discovered by LASSO and strongly correlated with radiation dose were Tube Current, kVp, Weight, Width of collimator, and Reference milliampere-seconds. A human expert validation of the outlier detection algorithm has yielded specificity of 0.85 [95% CI 0.78-0.92] and sensitivity of 0.91 [95% CI 0.85-0.97] (PPV = 0.84, NPV = 0.92). These values substantially outperform alternative methods we tested (F1 score 0.88 for our method against 0.51 for the alternatives). Conclusion: The study developed and tested a novel, automated method for processing CT scanner meta-data to identify CT exams where patients received an unwarranted amount of radiation. Radiation safety and protocol review committees may use this technique to uncover systemic issues and reduce future incidents. Keywords: Outlier detection, CT radiation dose safety, Regression model
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2352-0477
Relation: http://www.sciencedirect.com/science/article/pii/S2352047719300231; https://doaj.org/toc/2352-0477
DOI: 10.1016/j.ejro.2019.04.007
URL الوصول: https://doaj.org/article/18787ea8ed544683b5f3277a13a990c8
رقم الأكسشن: edsdoj.18787ea8ed544683b5f3277a13a990c8
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23520477
DOI:10.1016/j.ejro.2019.04.007