دورية أكاديمية

Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography

التفاصيل البيبلوغرافية
العنوان: Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography
المؤلفون: Reetta Hälvä, Satu M. Vaara, Juha I. Peltonen, Touko T. Kaasalainen, Miia Holmström, Jyri Lommi, Satu Suihko, Helena Rajala, Minna Kylmälä, Sari Kivistö, Suvi Syväranta
المصدر: Journal of Cardiovascular Magnetic Resonance, Vol 23, Iss 1, Pp 1-10 (2021)
بيانات النشر: Elsevier, 2021.
سنة النشر: 2021
المجموعة: LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: Aortic valve stenosis, 4D flow, 2D flow, Cardiovascular magnetic resonance, Valvular heart disease, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: Abstract Background Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. Methods We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 ± 11.3 years, aortic valve area 0.7 ± 0.1 cm2, and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland–Altman analysis. Results 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias − 1.1 m/s, limits of agreement ± 1.4 m/s) and 2D flow (bias − 1.2 m/s, limits of agreement ± 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7–6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9–6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7–5.1 m/s) were significant (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1532-429X
Relation: https://doaj.org/toc/1532-429X
DOI: 10.1186/s12968-021-00825-1
URL الوصول: https://doaj.org/article/19122bbd15184aa584c9f18cd6330af0
رقم الأكسشن: edsdoj.19122bbd15184aa584c9f18cd6330af0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1532429X
DOI:10.1186/s12968-021-00825-1