دورية أكاديمية

Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation

التفاصيل البيبلوغرافية
العنوان: Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation
المؤلفون: Malin Strasding, Samir Abou-Ayash, Thomas Laziok, Sam Doerken, Ralf-Joachim Kohal, Sebastian Berthold Maximilian Patzelt
المصدر: Materials, Vol 15, Iss 17, p 6137 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Technology
LCC:Electrical engineering. Electronics. Nuclear engineering
LCC:Engineering (General). Civil engineering (General)
LCC:Microscopy
LCC:Descriptive and experimental mechanics
مصطلحات موضوعية: removable partial denture, removable dental prosthesis, non-precious metal alloy, telescopic crown, patient satisfaction, patient-reported outcomes, Technology, Electrical engineering. Electronics. Nuclear engineering, TK1-9971, Engineering (General). Civil engineering (General), TA1-2040, Microscopy, QH201-278.5, Descriptive and experimental mechanics, QC120-168.85
الوصف: (1) Background: An alternative material to precious metal alloys are non-precious metal alloys. The material properties of these are different and, therefore, their clinical, biological and mechanical behaviors may also differ. Hence, the purpose of this in vivo investigation was to analyze the clinical and patient-reported outcomes of patients restored with non-precious metal alloy double crown-retained removable partial dentures (NP-D-RPDs). (2) Methods: Partially edentulous patients were restored with non-precious metal alloy partially veneered NP-D-RPDs. Survival rates, success rates, failures and patient-reported outcomes were investigated and statistically evaluated. (3) Results: A total of 61 patients (65.6 ± 10.8 years) were included and clinically and radiographically examined. The mean follow-up time was 25.2 ± 16.5 months. In total, 82 NP-D-RPDs and 268 abutment teeth were examined. The overall survival rate of the NP-D-RPDs was 100% after a mean follow-up time of 2.1 years. The overall success rate was 68.3%. The overall satisfaction with the NP-D-RPDs was 94.3%. (4) Conclusions: Non-precious metal alloy partially veneered NP-D-RPDs seem to be an efficient alternative to precious metal alloy RPDs with excellent patient-reported outcomes.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1996-1944
Relation: https://www.mdpi.com/1996-1944/15/17/6137; https://doaj.org/toc/1996-1944
DOI: 10.3390/ma15176137
URL الوصول: https://doaj.org/article/1af3b06e537c4431a91d8b2a4101f93e
رقم الأكسشن: edsdoj.1af3b06e537c4431a91d8b2a4101f93e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19961944
DOI:10.3390/ma15176137