Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom

التفاصيل البيبلوغرافية
العنوان: Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom
المؤلفون: Sergio Curto, Bassim Aklan, Tim Mulder, Oliver Mils, Manfred Schmidt, Ulf Lamprecht, Michael Peller, Ruediger Wessalowski, Lars H. Lindner, Rainer Fietkau, Daniel Zips, Gennaro G. Bellizzi, Netteke van Holthe, Martine Franckena, Margarethus M. Paulides, Gerard C. van Rhoon
المصدر: Cancers, Vol 11, Iss 11, p 1709 (2019)
بيانات النشر: MDPI AG, 2019.
سنة النشر: 2019
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: quality assurance, radiofrequency hyperthermia, magnetic resonance imaging-guided hyperthermia, magnetic resonance thermometry, thermistor probe, anthropomorphic phantom, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Clinical outcome of hyperthermia depends on the achieved target temperature, therefore target conformal heating is essential. Currently, invasive temperature probe measurements are the gold standard for temperature monitoring, however, they only provide limited sparse data. In contrast, magnetic resonance thermometry (MRT) provides unique capabilities to non-invasively measure the 3D-temperature. This study investigates MRT accuracy for MR-hyperthermia hybrid systems located at five European institutions while heating a centric or eccentric target in anthropomorphic phantoms with pelvic and spine structures. Scatter plots, root mean square error (RMSE) and Bland−Altman analysis were used to quantify accuracy of MRT compared to high resistance thermistor probe measurements. For all institutions, a linear relation between MRT and thermistor probes measurements was found with R2 (mean ± standard deviation) of 0.97 ± 0.03 and 0.97 ± 0.02, respectively for centric and eccentric heating targets. The RMSE was found to be 0.52 ± 0.31 °C and 0.30 ± 0.20 °C, respectively. The Bland-Altman evaluation showed a mean difference of 0.46 ± 0.20 °C and 0.13 ± 0.08 °C, respectively. This first multi-institutional evaluation of MR-hyperthermia hybrid systems indicates comparable device performance and good agreement between MRT and thermistor probes measurements. This forms the basis to standardize treatments in multi-institution studies of MR-guided hyperthermia and to elucidate thermal dose-effect relations.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2072-6694
Relation: https://www.mdpi.com/2072-6694/11/11/1709; https://doaj.org/toc/2072-6694
DOI: 10.3390/cancers11111709
URL الوصول: https://doaj.org/article/1b5bad59f7974ab7993cc347557aa483
رقم الأكسشن: edsdoj.1b5bad59f7974ab7993cc347557aa483
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20726694
DOI:10.3390/cancers11111709