دورية أكاديمية

Comparison of astigmatism between glued and sutured scleral-fixated intraocular lens

التفاصيل البيبلوغرافية
العنوان: Comparison of astigmatism between glued and sutured scleral-fixated intraocular lens
المؤلفون: Nithya Nair, Vijay Mathur, Pawan G Kumar
المصدر: Delta Journal of Ophthalmology, Vol 23, Iss 4, Pp 248-254 (2022)
بيانات النشر: Wolters Kluwer Medknow Publications, 2022.
سنة النشر: 2022
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: astigmatism, glued iol, sfiol, Ophthalmology, RE1-994
الوصف: Background Posterior chamber intraocular lens implantation in the bag is the preferred mode of correcting aphakia. But, in certain circumstances, this is not possible, thereby requiring modalities of secondary fixation of intraocular lens (IOL). Purpose The aim of this study was to compare the postoperative astigmatism till six months after surgery between the sutured scleral-fixated IOL and the glued scleral-fixated IOL. Patients and methods This is a single-center, prospective, observational, open-label study comparing the postoperative outcome (till 6 months), including astigmatism and best-corrected visual acuity (BCVA), of sutured scleral-fixated intraocular lens (SFIOL) (Group 1) and glued SFIOL (Group 2). There were 25 patients in each group. Patients were followed up on day 1, first week, first, second, third, and sixth month postoperatively. During each postoperative visit, slit-lamp biomicroscopy was performed to evaluate the status of the cornea, anterior chamber, IOL, and position of haptics. Uncorrected visual acuity, BCVA, refraction, and keratometry values (corneal astigmatism) were noted. Cylindrical refraction denoted total astigmatism. The IOL astigmatism was derived by subtracting the corneal astigmatism from the total astigmatism. Results The difference in corneal astigmatism between the two groups was statistically significant at 1, 3, and 6 months postoperatively (P=0.004, 0.002, and 0.012, respectively). The final values at 6 months were 3.00±1.68 diopters (D) in the sutured SFIOL group and 2.08±0.56 D in the glued SFIOL group. The glued SFIOL group required less cylindrical correction till 6 months of follow-up. The BCVA, 6 months postoperatively, was 0.36±0.19 in Group 1 compared with 0.32±0.17 in Group 2, with no statistically significant difference (P=0.404). Conclusion Both techniques proved to be good options for the implantation of SFIOL, but glued SFIOL was better as it led to less astigmatism and hence the need for less spectacle correction.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1110-9173
2090-4835
Relation: http://www.djo.eg.net/article.asp?issn=1110-9173;year=2022;volume=23;issue=4;spage=248;epage=254;aulast=Nair; https://doaj.org/toc/1110-9173; https://doaj.org/toc/2090-4835
DOI: 10.4103/djo.djo_35_22
URL الوصول: https://doaj.org/article/1c123d97251e4d7894d6da458696e3e7
رقم الأكسشن: edsdoj.1c123d97251e4d7894d6da458696e3e7
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:11109173
20904835
DOI:10.4103/djo.djo_35_22