دورية أكاديمية

Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

التفاصيل البيبلوغرافية
العنوان: Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models
المؤلفون: Anderson Chun On Tsang, Simon Sui Man Lai, Wai Choi Chung, Abraham Yik Sau Tang, Gilberto Ka Kit Leung, Alexander Kai Kei Poon, Alfred Cheuk Hang Yu, Kwok Wing Chow
المصدر: Ultrasonography, Vol 34, Iss 2, Pp 98-108 (2015)
بيانات النشر: Korean Society of Ultrasound in Medicine, 2015.
سنة النشر: 2015
المجموعة: LCC:Medical technology
مصطلحات موضوعية: Intracranial aneurysm, Endovascular procedures, Flow diverter, Printing, three-dimensional, Ultrasonography, Medical technology, R855-855.5
الوصف: Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2288-5919
2288-5943
Relation: http://www.e-ultrasonography.org/upload/usg-14063.pdf; https://doaj.org/toc/2288-5919; https://doaj.org/toc/2288-5943
DOI: 10.14366/usg.14063
URL الوصول: https://doaj.org/article/1c4078f78b5a427d9ec794f15b9aed2f
رقم الأكسشن: edsdoj.1c4078f78b5a427d9ec794f15b9aed2f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22885919
22885943
DOI:10.14366/usg.14063