Six-lead electrocardiography compared to single-lead electrocardiography and photoplethysmography of a wrist-worn device for atrial fibrillation detection controlled by premature atrial or ventricular contractions: six is smarter than one

التفاصيل البيبلوغرافية
العنوان: Six-lead electrocardiography compared to single-lead electrocardiography and photoplethysmography of a wrist-worn device for atrial fibrillation detection controlled by premature atrial or ventricular contractions: six is smarter than one
المؤلفون: Justinas Bacevicius, Neringa Taparauskaite, Ricardas Kundelis, Daivaras Sokas, Monika Butkuviene, Guoste Stankeviciute, Zygimantas Abramikas, Aiste Pilkiene, Ernestas Dvinelis, Justina Staigyte, Julija Marinskiene, Deimile Audzijoniene, Marija Petrylaite, Edvardas Jukna, Albinas Karuzas, Vytautas Juknevicius, Rusne Jakaite, Viktorija Basyte-Bacevice, Neringa Bileisiene, Ignas Badaras, Margarita Kiseliute, Gintare Zarembaite, Modestas Gudauskas, Eugenijus Jasiunas, Linda Johnson, Vaidotas Marozas, Audrius Aidietis
المصدر: Frontiers in Cardiovascular Medicine, Vol 10 (2023)
بيانات النشر: Frontiers Media S.A., 2023.
سنة النشر: 2023
المجموعة: LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: wearable, smartWatch, multiple-lead ECG, telemedicine, mHealth, remote monitoring, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: BackgroundSmartwatches are commonly capable to record a lead-I-like electrocardiogram (ECG) and perform a photoplethysmography (PPG)-based atrial fibrillation (AF) detection. Wearable technologies repeatedly face the challenge of frequent premature beats, particularly in target populations for screening of AF.ObjectiveTo investigate the potential diagnostic benefit of six-lead ECG compared to single-lead ECG and PPG-based algorithm for AF detection of the wrist-worn device.Methods and resultsFrom the database of DoubleCheck-AF 249 adults were enrolled in AF group (n = 121) or control group of SR with frequent premature ventricular (PVCs) or atrial (PACs) contractions (n = 128). Cardiac rhythm was monitored using a wrist-worn device capable of recording continuous PPG and simultaneous intermittent six-lead standard-limb-like ECG. To display a single-lead ECG, the six-lead ECGs were trimmed to lead-I-like ECGs. Two diagnosis-blinded cardiologists evaluated reference, six-lead and single-lead ECGs as “AF”, “SR”, or “Cannot be concluded”. AF detection based on six-lead ECG, single-lead ECG, and PPG yielded a sensitivity of 99.2%, 95.7%, and 94.2%, respectively. The higher number of premature beats per minute was associated with false positive outcomes of single-lead ECG (18.80 vs. 5.40 beats/min, P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2297-055X
Relation: https://www.frontiersin.org/articles/10.3389/fcvm.2023.1160242/full; https://doaj.org/toc/2297-055X
DOI: 10.3389/fcvm.2023.1160242
URL الوصول: https://doaj.org/article/1f6be0dad4c548639288af7cebfe32bd
رقم الأكسشن: edsdoj.1f6be0dad4c548639288af7cebfe32bd
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2297055X
DOI:10.3389/fcvm.2023.1160242