The detailed corrosion performance of bioresorbable Mg-0.8Ca alloy in physiological solutions

التفاصيل البيبلوغرافية
العنوان: The detailed corrosion performance of bioresorbable Mg-0.8Ca alloy in physiological solutions
المؤلفون: A.S. Gnedenkov, S.L. Sinebryukhov, V.S. Filonina, V.S. Egorkin, A.Yu. Ustinov, V.I. Sergienko, S.V. Gnedenkov
المصدر: Journal of Magnesium and Alloys, Vol 10, Iss 5, Pp 1326-1350 (2022)
بيانات النشر: KeAi Communications Co., Ltd., 2022.
سنة النشر: 2022
المجموعة: LCC:Mining engineering. Metallurgy
مصطلحات موضوعية: Magnesium-calcium alloy, Biodegradation, Corrosion rate, Electrochemistry, Weight loss, Minimum essential medium, Mining engineering. Metallurgy, TN1-997
الوصف: The electrochemical behaviour of biodegradable magnesium alloy Mg-0.8Ca was evaluated in a mammalian cell culture medium (MEM) and NaCl solutions (0.9 wt.%, 0.3 wt.%) using traditional (EIS, PDP, OCP) and local scanning electrochemical (SVET, SIET with pH-selective microelectrode) methods at the micro- and meso-level. Corrosion rates of samples in two different media were determined using weight loss tests. The influence of testing media components, alloy composition and microstructure on the material's degradation process was determined. The SVET/SIET test parameters were optimized for in vitro investigation of the bioresorbable material surface. The mechanism of the alloy's bioresorption was suggested. The effect of microsized phases on the corrosion behaviour of the alloy was proved using complementary in situ monitoring and SKPFM measurements. The rapid degradation rate of the alloy is related to the presence of local microgalvanic cells formed by cathodic α-magnesium matrix and anodic Mg2Ca phase. The highest corrosion activity was revealed in the first 12 min of sample exposure to MEM, followed by stabilization of corrosion process due to the material's passivation. Using SEM-EDX analysis, micro-Raman spectroscopy and XPS analysis the composition of the corrosion products was determined. Degradation in MEM proceeds with a formation of magnesium-and-carbonate substituted hydroxyapatite-containing film on the sample's surface. The low possibility of application of Mg-0.8Ca alloy without coating protection in implant surgery was highlighted.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2213-9567
Relation: http://www.sciencedirect.com/science/article/pii/S221395672100311X; https://doaj.org/toc/2213-9567
DOI: 10.1016/j.jma.2021.11.027
URL الوصول: https://doaj.org/article/a20e47975967448996f76e1190d5e55a
رقم الأكسشن: edsdoj.20e47975967448996f76e1190d5e55a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22139567
DOI:10.1016/j.jma.2021.11.027