دورية أكاديمية

Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging

التفاصيل البيبلوغرافية
العنوان: Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging
المؤلفون: André H. Dias, Anne M. Smith, Vijay Shah, David Pigg, Lars C. Gormsen, Ole L. Munk
المصدر: EJNMMI Physics, Vol 9, Iss 1, Pp 1-18 (2022)
بيانات النشر: SpringerOpen, 2022.
سنة النشر: 2022
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Dynamic whole-body PET, FDG, Parametric imaging, Patlak, Input function, PBIF, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Purpose Contemporary PET/CT scanners can use 70-min dynamic whole-body (D-WB) PET to generate more quantitative information about FDG uptake than just the SUV by generating parametric images of FDG metabolic rate (MRFDG). The analysis requires the late (50–70 min) D-WB tissue data combined with the full (0–70 min) arterial input function (AIF). Our aim was to assess whether the use of a scaled population-based input function (sPBIF) obviates the need for the early D-WB PET acquisition and allows for a clinically feasible 20-min D-WB PET examination. Methods A PBIF was calculated based on AIFs from 20 patients that were D-WB PET scanned for 120 min with simultaneous arterial blood sampling. MRFDG imaging using PBIF requires that the area under the curve (AUC) of the sPBIF is equal to the AUC of the individual patient’s input function because sPBIF AUC bias translates into MRFDG bias. Special patient characteristics could affect the shape of their AIF. Thus, we validated the use of PBIF in 171 patients that were divided into 12 subgroups according to the following characteristics: diabetes, cardiac ejection fraction, blood pressure, weight, eGFR and age. For each patient, the PBIF was scaled to the aorta image-derived input function (IDIF) to calculate a sPBIF, and the AUC bias was calculated. Results We found excellent agreement between the AIF and IDIF at all times. For the clinical validation, the use of sPBIF led to an acceptable AUC bias of 1–5% in most subgroups except for patients with diabetes or patients with low eGFR, where the biases were marginally higher at 7%. Multiparametric MRFDG images based on a short 20-min D-WB PET and sPBIF were visually indistinguishable from images produced by the full 70-min D-WB PET and individual IDIF. Conclusions A short 20-min D-WB PET examination using PBIF can be used for multiparametric imaging without compromising the image quality or precision of MRFDG. The D-WB PET examination may therefore be used in clinical routine for a wide range of patients, potentially allowing for more precise quantification in e.g. treatment response imaging.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2197-7364
Relation: https://doaj.org/toc/2197-7364
DOI: 10.1186/s40658-022-00490-y
URL الوصول: https://doaj.org/article/ce230ec5d08045fc91cf41be7c2f2ec3
رقم الأكسشن: edsdoj.230ec5d08045fc91cf41be7c2f2ec3
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21977364
DOI:10.1186/s40658-022-00490-y