دورية أكاديمية

Bladder cancer risk stratification with the Oncuria 10-plex bead-based urinalysis assay using three different Luminex xMAP instrumentation platforms

التفاصيل البيبلوغرافية
العنوان: Bladder cancer risk stratification with the Oncuria 10-plex bead-based urinalysis assay using three different Luminex xMAP instrumentation platforms
المؤلفون: Hideki Furuya, Toru Sakatani, Sunao Tanaka, Kaoru Murakami, Richard T. Waldron, Wayne Hogrefe, Charles J. Rosser
المصدر: Journal of Translational Medicine, Vol 22, Iss 1, Pp 1-9 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
مصطلحات موضوعية: Bladder cancer, Fluorescence, Multiplex immunoassay, Magnetic bead, In vitro assay, Performance, Medicine
الوصف: Abstract Background No single marker of bladder cancer (BC) exists in urine samples with sufficient accuracy for disease diagnosis and treatment monitoring. The multiplex Oncuria BC assay noninvasively quantifies the concentration of 10 protein analytes in voided urine samples to quickly generate a unique molecular profile with proven BC diagnostic and treatment-tracking utility. Test adoption by diagnostic and research laboratories mandates reliably reproducible assay performance across a variety of instrumentation platforms used in different laboratories. Methods We compared the performance of the clinically validated Oncuria BC multiplex immunoassay when data output was generated on three different analyzer systems. Voided urine samples from 36 subjects (18 with BC and 18 Controls) were reacted with Oncuria test reagents in three 96-well microtiter plates on Day 1, and consecutively evaluated on the LED/image-based MagPix, and laser/flow-based Luminex 200 and FlexMap 3D (all xMAP instruments from Luminex Corp., Austin, TX) on Day 2. The BC assay uses magnetic bead-based fluorescence technology (xMAP, Multi-analyte profiling; Luminex) to simultaneously quantify 10 protein analytes in urine specimens [i.e., angiogenin (ANG), apolipoprotein E (ApoE), carbonic anhydrase IX (CA9), CXCL8/interleukin-8 (IL-8), matrix metalloproteinase-9 (MMP-9), matrix metalloproteinase-10 (MMP-10), serpin A1/alpha-1 anti-trypsin (A1AT), serpin E1/plasminogen activator inhibitor-1 (PAI-1), CD138/syndecan-1 (SDC1), and vascular endothelial growth factor-A (VEGF-A)]. All three analyzers quantify fluorescence signals generated by the Oncuria assay. Results All three platforms categorized all 10 analytes in identical samples at nearly identical concentrations, with variance across systems typically
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1479-5876
Relation: https://doaj.org/toc/1479-5876
DOI: 10.1186/s12967-023-04811-2
URL الوصول: https://doaj.org/article/2313805b4e1f43b4a5883d57f56a6e8e
رقم الأكسشن: edsdoj.2313805b4e1f43b4a5883d57f56a6e8e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14795876
DOI:10.1186/s12967-023-04811-2