دورية أكاديمية
Laparoendoscopic single site surgery in pediatric urology: does it require specialized tools?
العنوان: | Laparoendoscopic single site surgery in pediatric urology: does it require specialized tools? |
---|---|
المؤلفون: | Nishant Patel, Michael Santomauro, Sarah Marietti, George Chiang |
المصدر: | International Brazilian Journal of Urology, Vol 42, Iss 2, Pp 277-283 (2016) |
بيانات النشر: | Sociedade Brasileira de Urologia, 2016. |
سنة النشر: | 2016 |
المجموعة: | LCC:Diseases of the genitourinary system. Urology |
مصطلحات موضوعية: | Laparoscopy, Pediatrics, Surgical Procedures, Operative, Urology, Diseases of the genitourinary system. Urology, RC870-923 |
الوصف: | ABSTRACT Purpose: To describe our experience utilizing Laparoendoscopic single site (LESS) surgery in pediatric urology. Materials and Methods: Retrospective chart review was performed on LESS urologic procedures from November 2009 through March 2013. A total of 44 patients underwent 54 procedures including: nephrectomy (23), orchiopexy (14), varicocelectomy (9), orchiectomy (2), urachal cyst excision (3), and antegrade continence enema (3) (ACE). Results: Median patient age was 6.9 years old. Estimated blood loss (EBL), ranged from less than 5cc to 47cc for a bilateral nephrectomy. Operative time varied from 56 mins for varicocelectomy to a median of 360 minutes for a bilateral nephroureterectomy. Incision length ranged between 2 and 2.5cm. In our initial experience we used a commercial port. However, as we progressed, we were able to perform the majority of our procedures via adjacent fascial punctures for instrumentation at the single incision site. One patient did require conversion to an open procedure as a result of bleeding. Three complications were noted (6.8%), with two Clavien Grade 3b complications. Two patients required additional procedures at 1-year follow-up. Conclusions: The use of LESS applies to many pediatric urologic procedures, ideally for ablative procedures or simple reconstructive efforts. The use of adjacent fascial puncture sites for instrumentation can obviate the need for a commercial port or multiple trocars. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1677-6119 1677-5538 |
Relation: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382016000200277&lng=en&tlng=en; https://doaj.org/toc/1677-6119 |
DOI: | 10.1590/S1677-5538.IBJU.2014.0444 |
URL الوصول: | https://doaj.org/article/e238a50dc18545a7b23d411503e939ee |
رقم الأكسشن: | edsdoj.238a50dc18545a7b23d411503e939ee |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 16776119 16775538 |
---|---|
DOI: | 10.1590/S1677-5538.IBJU.2014.0444 |