دورية أكاديمية

Reduced detection rate of artificial intelligence in images obtained from untrained endoscope models and improvement using domain adaptation algorithm

التفاصيل البيبلوغرافية
العنوان: Reduced detection rate of artificial intelligence in images obtained from untrained endoscope models and improvement using domain adaptation algorithm
المؤلفون: Junseok Park, Youngbae Hwang, Hyun Gun Kim, Joon Seong Lee, Jin-Oh Kim, Tae Hee Lee, Seong Ran Jeon, Su Jin Hong, Bong Min Ko, Seokmin Kim
المصدر: Frontiers in Medicine, Vol 9 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: endoscopes, artificial intelligence, deep learning, generative adversarial network, domain adaptation algorithm, Medicine (General), R5-920
الوصف: A training dataset that is limited to a specific endoscope model can overfit artificial intelligence (AI) to its unique image characteristics. The performance of the AI may degrade in images of different endoscope model. The domain adaptation algorithm, i.e., the cycle-consistent adversarial network (cycleGAN), can transform the image characteristics into AI-friendly styles. We attempted to confirm the performance degradation of AIs in images of various endoscope models and aimed to improve them using cycleGAN transformation. Two AI models were developed from data of esophagogastroduodenoscopies collected retrospectively over 5 years: one for identifying the endoscope models, Olympus CV-260SL, CV-290 (Olympus, Tokyo, Japan), and PENTAX EPK-i (PENTAX Medical, Tokyo, Japan), and the other for recognizing the esophagogastric junction (EGJ). The AIs were trained using 45,683 standardized images from 1,498 cases and validated on 624 separate cases. Between the two endoscope manufacturers, there was a difference in image characteristics that could be distinguished without error by AI. The accuracy of the AI in recognizing gastroesophageal junction was >0.979 in the same endoscope-examined validation dataset as the training dataset. However, they deteriorated in datasets from different endoscopes. Cycle-consistent adversarial network can successfully convert image characteristics to ameliorate the AI performance. The improvements were statistically significant and greater in datasets from different endoscope manufacturers [original → AI-trained style, increased area under the receiver operating characteristic (ROC) curve, P-value: CV-260SL → CV-290, 0.0056, P = 0.0106; CV-260SL → EPK-i, 0.0182, P = 0.0158; CV-290 → CV-260SL, 0.0134, P < 0.0001; CV-290 → EPK-i, 0.0299, P = 0.0001; EPK-i → CV-260SL, 0.0215, P = 0.0024; and EPK-i → CV-290, 0.0616, P < 0.0001]. In conclusion, cycleGAN can transform the diverse image characteristics of endoscope models into an AI-trained style to improve the detection performance of AI.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2296-858X
Relation: https://www.frontiersin.org/articles/10.3389/fmed.2022.1036974/full; https://doaj.org/toc/2296-858X
DOI: 10.3389/fmed.2022.1036974
URL الوصول: https://doaj.org/article/e249349aab3e45b4aac5813ced1e1785
رقم الأكسشن: edsdoj.249349aab3e45b4aac5813ced1e1785
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2296858X
DOI:10.3389/fmed.2022.1036974