Diagnosis of Ion-Exchange Resin Depositions in Paraffin Sections Using Corrective Light and Electron Microscopy-NanoSuit Method

التفاصيل البيبلوغرافية
العنوان: Diagnosis of Ion-Exchange Resin Depositions in Paraffin Sections Using Corrective Light and Electron Microscopy-NanoSuit Method
المؤلفون: Mako Ooishi, Satoshi Yamada, Toshiya Itoh, Shiori Meguro, Haruna Yagi, Isao Kosugi, Toshihide Iwashita, Kazuya Shinmura, Kiyoshi Misawa, Takahiko Hariyama, Hideya Kawasaki
المصدر: Diagnostics, Vol 11, Iss 7, p 1193 (2021)
بيانات النشر: MDPI AG, 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: ion-exchange resin, NanoSuit, corrective light and electron microscopy, energy-dispersive X-ray spectroscopy, Medicine (General), R5-920
الوصف: Ion-exchange resins are commonly used to treat complications such as hyperkalemia, hyperphosphatemia, and hypercholesterolemia. Gastrointestinal complications may occur as side effects of such treatments. Sodium and calcium polystyrene sulfonate (PS-Ca) are cation-exchange resins comprising an insoluble structure that binds to potassium ions in the digestive tract and exchanges them with sodium and calcium ions, respectively, to promote their elimination. PS crystals are rhomboid, refractive, and basophilic in hematoxylin and eosin staining. To differentiate PS crystals from other ion-exchange resin crystals such as sevelamer and cholestyramine, periodic acid–Schiff, Ziehl–Neelsen, and Congo red staining are usually performed. Here, correlative light and electron microscopy (CLEM)-energy-dispersive X-ray spectroscopy and the NanoSuit method (CENM) was applied to perform a definitive identification of ion-exchange resins. CENM could detect sulfur in PS crystals without destroying the glass slides. Notably, PS retained its ion-exchange ability to bind potassium in paraffin sections. Differential diagnosis of anion-exchange resins, such as sevelamer and cholestyramine, was possible using these characteristics. The phosphorus:carbon ratio was higher in sevelamer than in cholestyramine after soaking paraffin sections in a phosphate solution. Therefore, CENM may be used for the differential pathological diagnosis of ion-exchange resins in paraffin sections.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-4418
Relation: https://www.mdpi.com/2075-4418/11/7/1193; https://doaj.org/toc/2075-4418
DOI: 10.3390/diagnostics11071193
URL الوصول: https://doaj.org/article/2fdf392e651c482cbdeba3024c973629
رقم الأكسشن: edsdoj.2fdf392e651c482cbdeba3024c973629
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20754418
DOI:10.3390/diagnostics11071193