دورية أكاديمية

Endovascular Treatment of Complex Intracranial Aneurysms With LEO+ Stents: The LEO II Cohort Study

التفاصيل البيبلوغرافية
العنوان: Endovascular Treatment of Complex Intracranial Aneurysms With LEO+ Stents: The LEO II Cohort Study
المؤلفون: Omer F. Eker, Olivier Levrier, Emmanuel Houdart, Marianne Bonja, Denis Herbreteau, Alain Bonafé, Hubert Desal, the LEO+ II Investigators
المصدر: Frontiers in Neurology, Vol 13 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: intracranial aneurysm, wide neck aneurysm, stent-assisted coil embolization, efficacy, safety, LEO+ stent, Neurology. Diseases of the nervous system, RC346-429
الوصف: IntroductionStent-assisted coiling is an established treatment option for intracranial aneurysms, particularly, wide neck aneurysms with complex anatomy. The purpose of the present study was to assess the safety and efficacy of LEO+ stents in the treatment of intracranial aneurysms.Materials and MethodsA prospective, observational, multicenter study including 12 centers was performed on patients with ruptured, unruptured, and recanalized intracranial aneurysms treated with LEO+ stents. The primary efficacy endpoint was the rate of complete aneurysmal occlusion at 18 months post-procedure, and the primary safety endpoint was the morbidity and mortality at 18 months post-procedure.ResultsFrom March 2015 to June 2017, 176 patients were enrolled (mean age of 54.8 ± 11.5 years; 65.9% women). The aneurysms were located mainly in the anterior communicating artery (29.2%) and the middle cerebral artery (28.6%). They were mostly saccular (94%), with a mean dome size of 5.3 ± 2.6 mm and a mean aspect ratio of 1.2 ± 1.0. In total, 3% of the aneurysms were treated in the acute phase of rupture. Complete/nearly complete aneurysmal occlusion and major recanalization were observed in 89% (n = 146/164) and 1.8% (n = 3/164) of patients at 18-month follow-up, respectively. The LEO+ related mortality rate was 0.6% (n = 1/170), the morbidity rate was 4.1% (n = 7/170), and these patients were mRS 0–2 at 18 months.ConclusionOur results reflecting the use of LEO+ stents in real-world conditions confirm the efficacy and safety of LEO+ stents in the management of complex intracranial aneurysms.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-2295
Relation: https://www.frontiersin.org/articles/10.3389/fneur.2022.848683/full; https://doaj.org/toc/1664-2295
DOI: 10.3389/fneur.2022.848683
URL الوصول: https://doaj.org/article/31e04170fce9430e82d21193a15d61be
رقم الأكسشن: edsdoj.31e04170fce9430e82d21193a15d61be
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16642295
DOI:10.3389/fneur.2022.848683