دورية أكاديمية

Three-dimensional-printed customized prosthesis for pubic defect: prosthesis design and surgical techniques

التفاصيل البيبلوغرافية
العنوان: Three-dimensional-printed customized prosthesis for pubic defect: prosthesis design and surgical techniques
المؤلفون: Yuqi Zhang, Li Min, Minxun Lu, Jie Wang, Yitian Wang, Yi Luo, Yong Zhou, Hong Duan, Chongqi Tu
المصدر: Journal of Orthopaedic Surgery and Research, Vol 15, Iss 1, Pp 1-8 (2020)
بيانات النشر: BMC, 2020.
سنة النشر: 2020
المجموعة: LCC:Orthopedic surgery
LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: 3D-printed, Prosthesis, Type III hemipelvectomy, Design solution, Surgical technique, Orthopedic surgery, RD701-811, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background This study is to describe the detailed design and surgical techniques of three-dimensional (3D)-printed customized prosthesis for pubic bone defect. Patients and methods Five patients under type III resections were included in this study. Based on radiography data, 3D pelvic model was established and virtual surgery was simulated. Detailed anatomy data were measured including the size and arc of normal pubis, the size of residual bone in acetabular side. Different fixation ways were considered according to shape of defect. After features modification and porous structure design, prostheses were fabricated. The osteotomy guides and plastic models were used during surgery. Result Of 5 cases, the prostheses consist of the type with stem (3, 60%) and the type without stem (2, 40%). Mean follow-up period was 13.6 months (range, 8-24 months). For partial pubis removed cases, the mean length and width of narrowest part of normal superior pubis were 13.19 mm (range, 12.51-14.12 mm) and 7.80 mm (range, 7.18-8.26 mm) respectively. Mean arc of normal pubis was 2.71 rad (range, 2.66-2.73 rad). For the entire pubis resection cases, the mean diameter of narrowest parts and length of normal superior pubis were 11.52 mm (range, 11.13-11.91 mm) and 64.78 mm (range, 63.46-66.09 mm), while the diameter of narrowest part and length of normal inferior pubis were 7.37 mm (range, 7.20-7.54 mm) and 86.43 mm (range, 84.28-88.57 mm). Mean length and arc of intramedullary stem was 20 mm (range, 18-21 mm) and 2.7 rad. Mean screw holes number was 6.3 (range, 6-7) while ultimate screws number in surgeries was 4.3 (range, 4-5). Porous structure with 600-μm-pore size and 70% porosity was applied in parts of contact with residual bone. Conclusion 3D-printed customized prostheses could be a feasible option to reconstruct bone defect after type III resection. The design of 3D-printed customized prostheses is a multi-step process which is based on strict anatomic measurement.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1749-799X
Relation: http://link.springer.com/article/10.1186/s13018-020-01766-8; https://doaj.org/toc/1749-799X
DOI: 10.1186/s13018-020-01766-8
URL الوصول: https://doaj.org/article/320c05b9bf2d4be8a91c2a93e8cccd39
رقم الأكسشن: edsdoj.320c05b9bf2d4be8a91c2a93e8cccd39
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1749799X
DOI:10.1186/s13018-020-01766-8