دورية أكاديمية

Development and Evaluation of a Webcam-Based Digital X-Ray Machine Detector with Variable Current and Light Intensity Settings

التفاصيل البيبلوغرافية
العنوان: Development and Evaluation of a Webcam-Based Digital X-Ray Machine Detector with Variable Current and Light Intensity Settings
المؤلفون: Revindo Sulthon Narendra, Muhammad Ridha Mak’ruf, Triwiyanto Triwiyanto, Yassin Nimir
المصدر: Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, Vol 5, Iss 4 (2023)
بيانات النشر: Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya, 2023.
سنة النشر: 2023
المجموعة: LCC:Medical technology
LCC:Biotechnology
مصطلحات موضوعية: x-ray machine, webcam, matlab, mse, Medical technology, R855-855.5, Biotechnology, TP248.13-248.65
الوصف: X-ray images typically appear as film sheets upon development after undergoing chemical processing. To address these challenges, endeavors were undertaken to create digital X-ray detectors utilizing more cost-effective equipment. This approach involves harnessing variations in current and light intensity to discern disparities in image quality. The noteworthy contribution of this study lies in its ability to exhibit inverted images captured through webcam cameras, subject to prior image processing via the MATLAB application. The utilized measurement ranges encompass 20, 32, and 40 mA, while maintaining a fixed irradiation duration of 1 second and varying the illumination intensity across low, medium, and high levels at a constant 60kV setting. The obtained measurements reveal that the X-Ray Image Capture Device can be juxtaposed with images produced by the Philip brand Digital Radiography, evaluated through the acquired Mean Squared Error (MSE) values. The best picture in this experiment is using system parameter settings with kv of 60kV, 20mA and with low light intensity, and using the PH101 phototransitor. Conversely, the least favorable image records an MSE value of 66.4552 under 60kV 20mA conditions, employing the PH101 Phototransistor sensor and high light intensity. In summary, the outcomes of this study indicate the efficacy of the tool in capturing X-ray images
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2656-8624
Relation: https://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/328; https://doaj.org/toc/2656-8624
DOI: 10.35882/ijeeemi.v5i4.328
URL الوصول: https://doaj.org/article/338c6329fcdc41849a1a5f8edfefded9
رقم الأكسشن: edsdoj.338c6329fcdc41849a1a5f8edfefded9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26568624
DOI:10.35882/ijeeemi.v5i4.328