Clinical Results and Aortic Remodeling After Endovascular Treatment for Complicated Type B Aortic Dissection With the 'Fabulous' Stent System

التفاصيل البيبلوغرافية
العنوان: Clinical Results and Aortic Remodeling After Endovascular Treatment for Complicated Type B Aortic Dissection With the 'Fabulous' Stent System
المؤلفون: Ruihan Wang, Yuanqing Kan, Mou Yang, Hongkun Zhang, Xiaoming Zhang, Xiangchen Dai, Shuiting Zhai, Hejie Hu, Xiwei Zhang, Bing Chen, Jianhua Huang, Xiao Qin, Zhanxiang Xiao, Xinwu Lu, Wei Guo, Yi Si, Weiguo Fu
المصدر: Frontiers in Cardiovascular Medicine, Vol 9 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: aortic dissection, aortic remodeling, composite device, thoracic endovascular aortic repair (TEVAR), bare stent, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: ObjectiveTo report the clinical outcomes and aortic remodeling after the implantation of a self-developed, biomechanically optimized, two-stage thoracic stent system named Fabulous.BackgroundGiven the efficacy of the PETTICOAT concept, the benefits of Fabulous and the behavior of remodeling in different segments need further investigation.MethodsThis is a prospective and multicenter study. From 2017 to 2019, 145 patients (mean age, 56.6 years; 88.3% male) from 14 centers were included in this cohort. The clinical results and core laboratory results were from a central electronic data capture system. Computed tomographic angiography was performed preoperatively, 1 month, 6 months and yearly thereafter and was used for volumetric analysis by 3mensio (Bilthoven, The Netherlands). After the 1-year follow-up, 97.2 and 87.6% of the clinical and imaging results of the eligible patients were available.ResultsBoth stent grafts and bare stents were successfully delivered in place in 100% of the patients. The 30-day mortality and 1-year freedom from all-cause mortality were 2.1 and 96.6%, respectively. The incidence of entry flow was 11.7% at 30 days and 6.2% at 365 days. No cases of stent-induced new entry (SINE) or reintervention were observed. After the 1-year follow-up, the true lumen/overall volume ratio reached 88%. The following subdivided segment volume changes were recorded: stent graft segment TL +56%; FL −92%, bare stent segment TL +32%; FL −75%, and there were no significant changes in the visceral segment.ConclusionsThese outcomes indicated that there were favorable clinical benefits of Fabulous stent system. This device achieved a low short-term mortality and a low incidence of reintervention. In addition, patients undergoing Fabulous stent system implantation showed remodeling both on descending aorta and on the distal aorta. The volume changes in the TL and FL varied in the different segments. The long-term follow-up is still ongoing.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2297-055X
Relation: https://www.frontiersin.org/articles/10.3389/fcvm.2022.817675/full; https://doaj.org/toc/2297-055X
DOI: 10.3389/fcvm.2022.817675
URL الوصول: https://doaj.org/article/c34bc20f1940478a98dd2851238df6f6
رقم الأكسشن: edsdoj.34bc20f1940478a98dd2851238df6f6
قاعدة البيانات: Directory of Open Access Journals