Joint k-ω Space Image Reconstruction and Data Fitting for Chemical Exchange Saturation Transfer Magnetic Resonance Imaging

التفاصيل البيبلوغرافية
العنوان: Joint k-ω Space Image Reconstruction and Data Fitting for Chemical Exchange Saturation Transfer Magnetic Resonance Imaging
المؤلفون: Yuting Peng, Yan Dai, Shu Zhang, Jie Deng, Xun Jia
المصدر: Tomography, Vol 10, Iss 7, Pp 1123-1138 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Computer applications to medicine. Medical informatics
مصطلحات موضوعية: CEST, jointreconstruction, data fitting, Z-spectra, Computer applications to medicine. Medical informatics, R858-859.7
الوصف: Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) is a novel MRI technology to image certain compounds at extremely low concentrations. Long acquisition time to measure signals at a set of offset frequencies of the Z-spectra and to repeat measurements to reduce noise pose significant challenges to its applications. This study explores correlations of CEST MR images along the spatial and Z-spectral dimensions to improve MR image quality and robustness of magnetization transfer ratio (MTR) asymmetry estimation via a joint k-ω reconstruction model. The model was formulated as an optimization problem with respect to MR images at all frequencies ω, while incorporating regularizations along the spatial and spectral dimensions. The solution was subject to a self-consistency condition that the Z-spectrum of each pixel follows a multi-peak data fitting model corresponding to different CEST pools. The optimization problem was solved using the alternating direction method of multipliers. The proposed joint reconstruction method was evaluated on a simulated CEST MRI phantom and semi-experimentally on choline and iopamidol phantoms with added Gaussian noise of various levels. Results demonstrated that the joint reconstruction method was more tolerable to noise and reduction in number of offset frequencies by improving signal-to-noise ratio (SNR) of the reconstructed images and reducing uncertainty in MTR asymmetry estimation. In the choline and iopamidol phantom cases with 10.5% noise in the measurement data, our method achieved an averaged SNR of 31.0 dB and 32.2 dB compared to the SNR of 24.7 dB and 24.4 dB in the conventional reconstruction approach. It reduced uncertainty of the MTR asymmetry estimation over all regions of interest by 54.4% and 43.7%, from 1.71 and 2.38 to 0.78 and 1.71, respectively.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2379-139X
2379-1381
Relation: https://www.mdpi.com/2379-139X/10/7/85; https://doaj.org/toc/2379-1381; https://doaj.org/toc/2379-139X
DOI: 10.3390/tomography10070085
URL الوصول: https://doaj.org/article/364987bdcfed497a9756ccf49eb27829
رقم الأكسشن: edsdoj.364987bdcfed497a9756ccf49eb27829
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2379139X
23791381
DOI:10.3390/tomography10070085