Multicentric investigation on the safety, feasibility and usability of the ABLE lower-limb robotic exoskeleton for individuals with spinal cord injury: a framework towards the standardisation of clinical evaluations

التفاصيل البيبلوغرافية
العنوان: Multicentric investigation on the safety, feasibility and usability of the ABLE lower-limb robotic exoskeleton for individuals with spinal cord injury: a framework towards the standardisation of clinical evaluations
المؤلفون: Mark Andrew Wright, Franziska Herzog, Anna Mas-Vinyals, Alfons Carnicero-Carmona, Joan Lobo-Prat, Cornelia Hensel, Steffen Franz, Norbert Weidner, Joan Vidal, Eloy Opisso, Rüdiger Rupp
المصدر: Journal of NeuroEngineering and Rehabilitation, Vol 20, Iss 1, Pp 1-18 (2023)
بيانات النشر: BMC, 2023.
سنة النشر: 2023
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: Spinal cord injury, Spinal cord disorder, Exoskeleton, Rehabilitation, Robotics, Safety, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: Abstract Background Robotic lower-limb exoskeletons have the potential to provide additional clinical benefits for persons with spinal cord injury (SCI). However, high variability between protocols does not allow the comparison of study results on safety and feasibility between different exoskeletons. We therefore incorporated key aspects from previous studies into our study protocol and accordingly conducted a multicentre study investigating the safety, feasibility and usability of the ABLE Exoskeleton in clinical settings. Methods In this prospective pretest-posttest quasi-experimental study across two SCI centres in Germany and Spain, in- and outpatients with SCI were recruited into a 12-session training and assessment protocol, utilising the ABLE Exoskeleton. A follow-up visit after 4 weeks was included to assess after-training outcomes. Safety outcomes (device-related adverse events (AEs), number of drop-outs), feasibility and usability measures (level of assistance, donning/doffing-time) were recorded at every session together with changes in gait parameters and function. Patient-reported outcome measures including the rate of perceived exertion (RPE) and the psychosocial impact of the device were performed. Satisfaction with the device was evaluated in both participants and therapists. Results All 24 participants (45 ± 12 years), with mainly subacute SCI (
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1743-0003
Relation: https://doaj.org/toc/1743-0003
DOI: 10.1186/s12984-023-01165-0
URL الوصول: https://doaj.org/article/3806660fe5e34636a6e0dd0edd31e6b4
رقم الأكسشن: edsdoj.3806660fe5e34636a6e0dd0edd31e6b4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17430003
DOI:10.1186/s12984-023-01165-0