دورية أكاديمية

New trapezoid-shaped Frisch-grid ionization chamber for low-energy particle measurements

التفاصيل البيبلوغرافية
العنوان: New trapezoid-shaped Frisch-grid ionization chamber for low-energy particle measurements
المؤلفون: Tianli Qiu, Yuansheng Yang, Xiaohua Yuan, Peng Ma, Meng Li, Junwei Zhang, Dong Guo, Yuxuan Yang, Xianglun Wei, Zhoubo He, Xiaohao Yin, Xinjie Huang, Haichuan Zou, Zhijie Li, Zhixuan He, Chengui Lu, Rongjiang Hu, Hooi Jin Ong, Herun Yang, Zhigang Xiao, Hongwei Wang, Limin Duan
المصدر: European Physical Journal C: Particles and Fields, Vol 82, Iss 10, Pp 1-11 (2022)
بيانات النشر: SpringerOpen, 2022.
سنة النشر: 2022
المجموعة: LCC:Astrophysics
LCC:Nuclear and particle physics. Atomic energy. Radioactivity
مصطلحات موضوعية: Astrophysics, QB460-466, Nuclear and particle physics. Atomic energy. Radioactivity, QC770-798
الوصف: Abstract A new trapezoid-shaped Frisch-grid ionization chamber (TFG-IC) has been built as a part of a $$\varDelta {E}-E$$ Δ E - E telescope system for the detection and identification of charged particles at energies down to a few MeV. To study the effect of the drift electric field uniformity, two types of sealed windows, namely a pair of SSA (split-strip aluminized mylar film) and a pair of DSA (double-sided aluminized mylar film) sealed windows have been investigated. The detector’s performances were studied using a standard $$^{241}$$ 241 Am source at different gas pressures, and the total energy-deposit resolution achieved is about 1.1%(FWHM). The $$\varDelta {E}-E$$ Δ E - E telescope, which was composed of TFG-IC and a DSSSD (double-sided silicon strip detector), has been tested using a three-component $$\alpha $$ α source and the $$^{241}$$ 241 Am source under laboratory conditions. The results show that the energy resolution with the SSA sealed windows which provide uniform drift electric field has a smaller fluctuation than that with the DSA ones; the fluctuations are about 1% and 4% for the former and the latter, respectively. Simulations using the COMSOL software also confirmed the electric-field distortion at the edge of the detector with the DSA windows. A correlation curve between energy resolution and energy deposit of charged particles at various gas pressures and for two gas species is derived for TFG-IC with the SSA sealed windows using the measurement with the $$^{241}$$ 241 Am source. Incorporating the above results, we performed Monte Carlo simulations to evaluate the particle-identification capability of the telescope. The results show that the telescope can be extended to the identification of low-energy particles.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1434-6052
Relation: https://doaj.org/toc/1434-6052
DOI: 10.1140/epjc/s10052-022-10953-2
URL الوصول: https://doaj.org/article/385a5f5399684fa7b199762b78540a55
رقم الأكسشن: edsdoj.385a5f5399684fa7b199762b78540a55
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14346052
DOI:10.1140/epjc/s10052-022-10953-2