دورية أكاديمية

Enhancing Early Detection of Sepsis in Neonates through Multimodal Biosignal Integration: A Study of Pulse Oximetry, Near-Infrared Spectroscopy (NIRS), and Skin Temperature Monitoring

التفاصيل البيبلوغرافية
العنوان: Enhancing Early Detection of Sepsis in Neonates through Multimodal Biosignal Integration: A Study of Pulse Oximetry, Near-Infrared Spectroscopy (NIRS), and Skin Temperature Monitoring
المؤلفون: Nicoleta Lungu, Daniela-Eugenia Popescu, Ana Maria Cristina Jura, Mihaela Zaharie, Mihai-Andrei Jura, Ioana Roșca, Mărioara Boia
المصدر: Bioengineering, Vol 11, Iss 7, p 681 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Technology
LCC:Biology (General)
مصطلحات موضوعية: neonatal sepsis, biosignals, early detection, preterm newborn, pulse oximetry, NIRS, Technology, Biology (General), QH301-705.5
الوصف: Sepsis continues to be challenging to diagnose due to its non-specific clinical signs and symptoms, emphasizing the importance of early detection. Our study aimed to enhance the accuracy of sepsis diagnosis by integrating multimodal monitoring technologies with conventional diagnostic methods. The research included a total of 121 newborns, with 39 cases of late-onset sepsis, 35 cases of early-onset sepsis, and 47 control subjects. Continuous monitoring of biosignals, including pulse oximetry (PO), near-infrared spectroscopy (NIRS), and skin temperature (ST), was conducted. An algorithm was then developed in Python to identify early signs of sepsis. The model demonstrated the capability to detect sepsis 6 to 48 h in advance with an accuracy rate of 87.67 ± 7.42%. Sensitivity and specificity were recorded at 76% and 90%, respectively, with NIRS and ST having the most significant impact on predictive accuracy. Despite the promising results, limitations such as sample size, data variability, and potential biases were noted. These findings highlight the critical role of non-invasive biosensing methods in conjunction with conventional biomarkers and cultures, offering a strong foundation for early sepsis detection and improved neonatal care. Further research should be conducted to validate these results across different clinical settings.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2306-5354
Relation: https://www.mdpi.com/2306-5354/11/7/681; https://doaj.org/toc/2306-5354
DOI: 10.3390/bioengineering11070681
URL الوصول: https://doaj.org/article/392fdad0c0784e2ab2beea122726c57f
رقم الأكسشن: edsdoj.392fdad0c0784e2ab2beea122726c57f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23065354
DOI:10.3390/bioengineering11070681