دورية أكاديمية

Comparison of the efficacy and comfort of high-flow nasal cannula with different initial flow settings in patients with acute hypoxemic respiratory failure: a systematic review and network meta-analysis

التفاصيل البيبلوغرافية
العنوان: Comparison of the efficacy and comfort of high-flow nasal cannula with different initial flow settings in patients with acute hypoxemic respiratory failure: a systematic review and network meta-analysis
المؤلفون: Yuewen He, Xuhui Zhuang, Hao Liu, Wuhua Ma
المصدر: Journal of Intensive Care, Vol 11, Iss 1, Pp 1-23 (2023)
بيانات النشر: BMC, 2023.
سنة النشر: 2023
المجموعة: LCC:Medical emergencies. Critical care. Intensive care. First aid
مصطلحات موضوعية: High-flow nasal cannula, Acute hypoxemic respiratory failure, Network meta-analysis, Medical emergencies. Critical care. Intensive care. First aid, RC86-88.9
الوصف: Abstract Background High-flow nasal cannula (HFNC) has been proven effective in improving patients with acute hypoxemic respiratory failure (AHRF), but a discussion of its use for initial flow settings still need to be provided. We aimed to compare the effectiveness and comfort evaluation of HFNC with different initial flow settings in patients with AHRF. Methods Studies published by October 10, 2022, were searched exhaustively in PubMed, Embase, Web of Science, Cochrane Library (CENTRAL), and the China National Knowledge Infrastructure (CNKI) database. Network meta-analysis (NMA) was performed with STATA 17.0 and R software (version 4.2.1). A Bayesian framework was applied for this NMA. Comparisons of competing models based on the deviance information criterion (DIC) were used to select the best model for NMA. The primary outcome is the intubation at day 28. Secondary outcomes included short-term and long-term mortality, comfort score, length of ICU or hospital stay, and 24-h PaO2/FiO2. Results This NMA included 23 randomized controlled trials (RCTs) with 5774 patients. With NIV as the control, the HFNC_high group was significantly associated with lower intubation rates (odds ratio [OR] 0.72 95% credible interval [CrI] 0.56 to 0.93; moderate quality evidence) and short-term mortality (OR 0.81 95% CrI 0.69 to 0.96; moderate quality evidence). Using HFNC_Moderate (Mod) group (mean difference [MD] − 1.98 95% CrI -3.98 to 0.01; very low quality evidence) as a comparator, the HFNC_Low group had a slight advantage in comfort scores but no statistically significant difference. Of all possible interventions, the HFNC_High group had the highest probability of being the best in reducing intubation rates (73.04%), short-term (82.74%) and long-term mortality (67.08%). While surface under the cumulative ranking curve value (SUCRA) indicated that the HFNC_Low group had the highest probability of being the best in terms of comfort scores. Conclusions The high initial flow settings (50–60 L/min) performed better in decreasing the occurrence of intubation and mortality, albeit with poor comfort scores. Treatment of HFNC for AHRF patients ought to be initiated from moderate flow rates (30–40 L/min), and individualized flow settings can make HFNC more sensible in clinical practice.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2052-0492
Relation: https://doaj.org/toc/2052-0492
DOI: 10.1186/s40560-023-00667-2
URL الوصول: https://doaj.org/article/3a8cae540c8444feaed9b11ff9f7aaef
رقم الأكسشن: edsdoj.3a8cae540c8444feaed9b11ff9f7aaef
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20520492
DOI:10.1186/s40560-023-00667-2