دورية أكاديمية

Label-Free Cyanobacteria Quantification Using a Microflow Cytometry Platform for Early Warning Detection and Characterization of Hazardous Cyanobacteria Blooms

التفاصيل البيبلوغرافية
العنوان: Label-Free Cyanobacteria Quantification Using a Microflow Cytometry Platform for Early Warning Detection and Characterization of Hazardous Cyanobacteria Blooms
المؤلفون: Yushan Zhang, Andres Escobar, Tianyi Guo, Chang-Qing Xu
المصدر: Micromachines, Vol 14, Iss 5, p 965 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Mechanical engineering and machinery
مصطلحات موضوعية: phycocyanin, cyanobacteria, microfluidics, fluorescence, microflow cytometer, Microcystis aeruginosa, Mechanical engineering and machinery, TJ1-1570
الوصف: The eutrophication of aquatic ecosystems caused by rapid human urbanization has led to an increased production of potentially hazardous bacterial populations, known as blooms. One of the most notorious forms of these aquatic blooms are cyanobacteria, which in sufficiently large quantities can pose a hazard to human health through ingestion or prolonged exposure. Currently, one of the greatest difficulties in regulating and monitoring these potential hazards is the early detection of cyanobacterial blooms, in real time. Therefore, this paper presents an integrated microflow cytometry platform for label-free phycocyanin fluorescence detection, which can be used for the rapid quantification of low-level cyanobacteria and provide early warning alerts for potential harmful cyanobacterial blooms. An automated cyanobacterial concentration and recovery system (ACCRS) was developed and optimized to reduce the assay volume, from 1000 mL to 1 mL, to act as a pre-concentrator and subsequently enhance the detection limit. The microflow cytometry platform utilizes an on-chip laser-facilitated detection to measure the in vivo fluorescence emitted from each individual cyanobacterial cell, as opposed to measuring overall fluorescence of the whole sample, potentially decreasing the detection limit. By applying transit time and amplitude thresholds, the proposed cyanobacteria detection method was verified by the traditional cell counting technique using a hemocytometer with an R2 value of 0.993. It was shown that the limit of quantification of this microflow cytometry platform can be as low as 5 cells/mL for Microcystis aeruginosa, 400-fold lower than the Alert Level 1 (2000 cells/mL) set by the World Health Organization (WHO). Furthermore, the decreased detection limit may facilitate the future characterization of cyanobacterial bloom formation to better provide authorities with ample time to take the appropriate actions to mitigate human risk from these potentially hazardous blooms.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2072-666X
Relation: https://www.mdpi.com/2072-666X/14/5/965; https://doaj.org/toc/2072-666X
DOI: 10.3390/mi14050965
URL الوصول: https://doaj.org/article/3adf4cb03e0249938721c4edad7fcd1d
رقم الأكسشن: edsdoj.3adf4cb03e0249938721c4edad7fcd1d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2072666X
DOI:10.3390/mi14050965