دورية أكاديمية

ID22 – the high-resolution powder-diffraction beamline at ESRF

التفاصيل البيبلوغرافية
العنوان: ID22 – the high-resolution powder-diffraction beamline at ESRF
المؤلفون: Andrew Fitch, Catherine Dejoie, Ezio Covacci, Giorgia Confalonieri, Ola Grendal, Laurent Claustre, Perceval Guillou, Jérôme Kieffer, Wout de Nolf, Sébastien Petitdemange, Marie Ruat, Yves Watier
المصدر: Journal of Synchrotron Radiation, Vol 30, Iss 5, Pp 1003-1012 (2023)
بيانات النشر: International Union of Crystallography, 2023.
سنة النشر: 2023
المجموعة: LCC:Nuclear and particle physics. Atomic energy. Radioactivity
LCC:Crystallography
مصطلحات موضوعية: powder x-ray diffraction, high resolution, esrf, pdf analysis, Nuclear and particle physics. Atomic energy. Radioactivity, QC770-798, Crystallography, QD901-999
الوصف: Following Phase 2 of the upgrade of the ESRF in which the storage ring was replaced by a new low-emittance ring along with many other facility upgrades, the status of ID22, the high-resolution powder-diffraction beamline, is described. The beamline has an in-vacuum undulator as source providing X-rays in the range 6–75 keV. ID22's principle characteristics include very high angular resolution as a result of the highly collimated and monochromatic beam, coupled with a 13-channel Si 111 multi-analyser stage between the sample and a Dectris Eiger2 X 2M-W CdTe pixel detector. The detector's axial resolution allows recorded 2θ values to be automatically corrected for the effects of axial divergence, resulting in narrower and more-symmetric peaks compared with the previous fixed-axial-slit arrangement. The axial acceptance can also be increased with increasing diffraction angle, thus simultaneously improving the statistical quality of high-angle data. A complementary Perkin Elmer XRD1611 medical-imaging detector is available for faster, lower-resolution data, often used at photon energies of 60–70 keV for pair-distribution function analysis, although this is also possible in high-resolution mode by scanning up to 120° 2θ at 35 keV. There are various sample environments, allowing sample temperatures from 4 K to 1600°C, a capillary cell for non-corrosive gas atmospheres in the range 0–100 bar, and a sample-changing robot that can accommodate 75 capillary samples compatible with the temperature range 80 K to 950°C.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1600-5775
16005775
Relation: http://scripts.iucr.org/cgi-bin/paper?S1600577523004915; https://doaj.org/toc/1600-5775
DOI: 10.1107/S1600577523004915
URL الوصول: https://doaj.org/article/3e70df15058d4ea9adcdd834e9c6ba72
رقم الأكسشن: edsdoj.3e70df15058d4ea9adcdd834e9c6ba72
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16005775
DOI:10.1107/S1600577523004915