دورية أكاديمية

Transient Synchronous Stability Analysis of Grid-Forming Photovoltaic Grid-Connected Inverters during Asymmetrical Grid Faults

التفاصيل البيبلوغرافية
العنوان: Transient Synchronous Stability Analysis of Grid-Forming Photovoltaic Grid-Connected Inverters during Asymmetrical Grid Faults
المؤلفون: Wenwen He, Jun Yao, Hao Xu, Qinmin Zhong, Ruilin Xu, Yuming Liu, Xiaoju Li
المصدر: Energies, Vol 17, Iss 6, p 1399 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Technology
مصطلحات موضوعية: grid-forming photovoltaic grid-connected converter, transient synchronous stability, asymmetric grid faults, grid code, Technology
الوصف: Compared with the traditional grid-following photovoltaic grid-connected converter (GFL-PGC), the grid-forming photovoltaic grid-connected converter (GFM-PGC) can provide voltage and frequency support for power systems, which can effectively enhance the stability of power electronic power systems. Consequently, GFM-PGCs have attracted great attention in recent years. When an asymmetrical short-circuit fault occurs in the power grid, GFM-PGC systems may experience transient instability, which has been less studied so far. In this paper, a GFM-PGC system is investigated under asymmetrical short-circuit fault conditions. A novel Q-V droop control structure is proposed by improving the traditional droop control. The proposed control structure enables the system to accurately control the positive- and negative-sequence reactive current without switching the control strategy during the low-voltage ride-through (LVRT) period so that it can meet the requirements of the renewable energy grid code. In addition, a dual-loop control structure model of positive- and negative-sequence voltage and current is established for the GFM-PGC system under asymmetrical short-circuit fault conditions. Based on the symmetrical component method, the composite sequence network of the system is obtained under asymmetrical short-circuit fault conditions, and positive- and negative-sequence power-angle characteristic curves are analyzed. The influence law of system parameters on the transient synchronous stability of positive- and negative-sequence systems is quantitatively analyzed through the equal area criterion. Finally, the correctness of the theoretical analysis is verified by simulation and hardware-in-the-loop experiments.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1996-1073
Relation: https://www.mdpi.com/1996-1073/17/6/1399; https://doaj.org/toc/1996-1073
DOI: 10.3390/en17061399
URL الوصول: https://doaj.org/article/3f2024d0d445485681dbcea8285b8f83
رقم الأكسشن: edsdoj.3f2024d0d445485681dbcea8285b8f83
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19961073
DOI:10.3390/en17061399