Approximation of bicarbonate concentration using serum total carbon dioxide concentration in patients with non-dialysis chronic kidney disease

التفاصيل البيبلوغرافية
العنوان: Approximation of bicarbonate concentration using serum total carbon dioxide concentration in patients with non-dialysis chronic kidney disease
المؤلفون: Keiji Hirai, Saori Minato, Shohei Kaneko, Katsunori Yanai, Hiroki Ishii, Taisuke Kitano, Mitsutoshi Shindo, Haruhisa Miyazawa, Kiyonori Ito, Yuichirou Ueda, Yoshio Kaku, Taro Hoshino, Tatsuro Watano, Shinji Fujino, Susumu Ookawara, Kiyoka Omoto, Yoshiyuki Morishita
المصدر: Kidney Research and Clinical Practice, Vol 38, Iss 3, Pp 326-335 (2019)
بيانات النشر: The Korean Society of Nephrology, 2019.
سنة النشر: 2019
المجموعة: LCC:Internal medicine
LCC:Specialties of internal medicine
مصطلحات موضوعية: Acid base balance, Bicarbonates, Carbon dioxide, Chronic kidney disease, Internal medicine, RC31-1245, Specialties of internal medicine, RC581-951
الوصف: Background : We investigated the relationship between serum total carbon dioxide (CO2) and bicarbonate ion (HCO3−) concentrations in pre-dialysis chronic kidney disease (CKD) patients and devised a formula for predicting low bicarbonate (HCO3−< 24 mmol/L) and high bicarbonate (HCO3− ≥ 24 mmol/L) using clinical parameters. Methods : In total, 305 samples of venous blood collected from 207 pre-dialysis patients assessed by CKD stage (G1 + G2, 46; G3, 50; G4, 51; G5, 60) were investigated. The relationship between serum total CO2 and HCO3− concentrations was analyzed using Pearson's correlation coefficient. An approximation formula was developed using clinical parameters correlated independently with HCO3− concentration. Diagnostic accuracy of serum total CO2 and the approximation formula was evaluated by receiver operating characteristic curve analysis and a 2 × 2 table. Results : Serum total CO2 correlated strongly with HCO3− concentration (r = 0.91; P < 0.001). The following approximation formula was obtained by a multiple linear regression analysis: HCO3− (mmol/L) = total CO2 − 0.5 × albumin − 0.1 × chloride − 0.01 × (estimated glomerular filtration rate + blood glucose) + 15. The areas under the curves of serum total CO2 and the approximation formula for detection of low bicarbonate and high bicarbonate were 0.981, 0.996, 0.993, and 1.000, respectively. This formula had superior diagnostic accuracy compared with that of serum total CO2 (86.6% vs. 81.3%). Conclusion : Serum total CO2 correlated strongly with HCO3− concentration in pre-dialysis CKD patients. An approximation formula including serum total CO2 showed superior diagnostic accuracy for low and high bicarbonate compared with serum total CO2.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Korean
تدمد: 2211-9132
Relation: https://doaj.org/toc/2211-9132
DOI: 10.23876/j.krcp.19.027
URL الوصول: https://doaj.org/article/ce40c827156c47e3a4df7709a27708ad
رقم الأكسشن: edsdoj.40c827156c47e3a4df7709a27708ad
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22119132
DOI:10.23876/j.krcp.19.027