دورية أكاديمية

Noncontact Conjunctiva: A Better Mitomycin C Application Site for Trabeculectomy

التفاصيل البيبلوغرافية
العنوان: Noncontact Conjunctiva: A Better Mitomycin C Application Site for Trabeculectomy
المؤلفون: Yunru Liao, Yafen Liu, Xinbo Gao, Jiawei Ren, Huishan Lin, Yao Liu, Wei Huang, Chengguo Zuo, Mingkai Lin
المصدر: Ophthalmology and Therapy, Vol 12, Iss 3, Pp 1723-1735 (2023)
بيانات النشر: Adis, Springer Healthcare, 2023.
سنة النشر: 2023
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Trabeculectomy, Mitomycin C, Application position, Ophthalmology, RE1-994
الوصف: Abstract Introduction Bleb scarring is the most important complication of trabeculectomy. Changing the application position of mitomycin C (MMC) during trabeculectomy might affect the surgery outcome. Our aim is to compare the effectiveness and safety of intraocular pressure (IOP) lowering in two different application sites of mitomycin in trabeculectomy. Methods This retrospective trial compared the surgical outcomes of 177 eyes that underwent trabeculectomy with adjunctive mitomycin C. In 70 eyes, an MMC-soaked sponge was applied under the scleral flap without touching Tenon’s capsule. In 107 eyes, an MMC-soaked sponge was applied under the scleral flap covered by Tenon’s capsule. Outcome measures were the IOP, best-corrected visual acuity (BCVA), success rates, and incidence of complications. Results Within both groups, a highly significant IOP reduction was seen during follow-up. The effectiveness in reducing IOP and the change in best-corrected visual acuity (BCVA) were similar between the two groups. Thin-walled blebs and postoperative hypotony were seen more often when MMC-soaked sponges were applied under the scleral flap covered by Tenon’s capsule (P = 0.008 and P = 0.012, respectively). There was no significant difference in BCVA or other complications in either group. Conclusion Since the effectiveness of IOP reduction was similar between both groups and with a low incidence of thin-walled blebs and hypotony, the subscleral application without touching Tenon’s capsule seems to be the safer application site of MMC during trabeculectomy.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2193-8245
2193-6528
Relation: https://doaj.org/toc/2193-8245; https://doaj.org/toc/2193-6528
DOI: 10.1007/s40123-023-00706-z
URL الوصول: https://doaj.org/article/4165448b200b4a569867aa7e8c336dc3
رقم الأكسشن: edsdoj.4165448b200b4a569867aa7e8c336dc3
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21938245
21936528
DOI:10.1007/s40123-023-00706-z