دورية أكاديمية

Single-Element Dual-Interferometer for Precision Inertial Sensing: Sub-Picometer Structural Stability and Performance as a Reference for Laser Frequency Stabilization

التفاصيل البيبلوغرافية
العنوان: Single-Element Dual-Interferometer for Precision Inertial Sensing: Sub-Picometer Structural Stability and Performance as a Reference for Laser Frequency Stabilization
المؤلفون: Victor Huarcaya, Miguel Dovale Álvarez, Kohei Yamamoto, Yichao Yang, Stefano Gozzo, Pablo Martínez Cano, Moritz Mehmet, Juan José Esteban Delgado, Jianjun Jia, Gerhard Heinzel
المصدر: Sensors, Vol 23, Iss 24, p 9758 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Chemical technology
مصطلحات موضوعية: laser interferometry, inertial sensing, optical readout, Chemical technology, TP1-1185
الوصف: Future GRACE-like geodesy missions could benefit from adopting accelerometer technology akin to that of the LISA Pathfinder, which employed laser interferometric readout at the sub-picometer level in addition to the conventional capacitive sensing, which is at best at the level of 100 pm. Improving accelerometer performance holds great potential to enhance the scientific output of forthcoming missions, carrying invaluable implications for research in climate, water resource management, and disaster risk reduction. To reach sub-picometer displacement sensing precision in the millihertz range, laser interferometers rely on suppression of laser-frequency noise by several orders of magnitude. Many optical frequency stabilization methods are available with varying levels of complexity, size, and performance. In this paper, we describe the performance of a Mach–Zehnder interferometer based on a compact monolithic optic. The setup consists of a commercial fiber injector, a custom-designed pentaprism used to split and recombine the laser beam, and two photoreceivers placed at the complementary output ports of the interferometer. The structural stability of the prism is transferred to the laser frequency via amplification, integration, and feedback of the balanced-detection signal, achieving a fractional frequency instability better than 6 parts in 1013, corresponding to an interferometer pathlength stability better than 1pm/Hz. The prism was designed to host a second interferometer to interrogate the position of a test mass. This optical scheme has been dubbed “single-element dual-interferometer” or SEDI.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1424-8220
Relation: https://www.mdpi.com/1424-8220/23/24/9758; https://doaj.org/toc/1424-8220
DOI: 10.3390/s23249758
URL الوصول: https://doaj.org/article/447a06c85b0144ca8ca75bb7567c6879
رقم الأكسشن: edsdoj.447a06c85b0144ca8ca75bb7567c6879
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14248220
DOI:10.3390/s23249758