دورية أكاديمية

The Use of the Computer Tomography Method in the Analysis of the Microstructure of Materials Formed as a Result of Hydrothermal Treatment: Cellular Concretes

التفاصيل البيبلوغرافية
العنوان: The Use of the Computer Tomography Method in the Analysis of the Microstructure of Materials Formed as a Result of Hydrothermal Treatment: Cellular Concretes
المؤلفون: Anna Stepien, Ryszard Dachowski
المصدر: Journal of Composites Science, Vol 8, Iss 3, p 98 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Technology
LCC:Science
مصطلحات موضوعية: ACC, AAC, cellular concrete, HIPS, autoclaved materials, polystyrene, Technology, Science
الوصف: The subject of this research is sustainable construction and energy saving, which is most reflected in the technological aspects of building construction. This article focuses on single-family buildings, and the subject of this research is hollow blocks (blocks) created as a result of hydrothermal treatment, in this case, autoclaved aerated concrete (AAC) and autoclaved cellular concrete (ACC), both traditional and modified plastics (HIPS). There are two types of materials resulting from hydrothermal treatment: autoclaved sand-lime bricks and autoclaved concrete. Both in the case of ACC and silicates bricks, the basic substrates used during their production are lime, sand and water (cement is also added to cellular concrete). This article presents the methodology of testing the porous structure of autoclaved materials with the use of computed tomography. Aerated concrete (light autoclaved concrete) has a compressive strength of 2–6 MPa. The tests included aerated concrete modified with high-impact polystyrene, commonly known as HIPS. HIPS high-impact polystyrene is a thermoplastic polymer that is obtained by block suspension polymerization of styrene with the addition of synthetic rubber. As a result of polymerization, small particles of polybutadiene remain in the polystyrene male, changing its physical and mechanical properties. The results from the content of air voids in the autoclaved concrete sample were, on average, 52.53%.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2504-477X
Relation: https://www.mdpi.com/2504-477X/8/3/98; https://doaj.org/toc/2504-477X
DOI: 10.3390/jcs8030098
URL الوصول: https://doaj.org/article/457562fb22b24b15b637766c900361a5
رقم الأكسشن: edsdoj.457562fb22b24b15b637766c900361a5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2504477X
DOI:10.3390/jcs8030098