دورية أكاديمية

Comparison of antibody titers using conventional tube technique versus column agglutination technique in ABO blood group incompatible renal transplant

التفاصيل البيبلوغرافية
العنوان: Comparison of antibody titers using conventional tube technique versus column agglutination technique in ABO blood group incompatible renal transplant
المؤلفون: Amit Bhangale, Amardeep Pathak, Smita Pawar, Tarun Jeloka
المصدر: Asian Journal of Transfusion Science, Vol 11, Iss 2, Pp 131-134 (2017)
بيانات النشر: Wolters Kluwer Medknow Publications, 2017.
سنة النشر: 2017
المجموعة: LCC:Diseases of the blood and blood-forming organs
مصطلحات موضوعية: ABO incompatible kidney transplants, column agglutination technique, conventional tube technique, Diseases of the blood and blood-forming organs, RC633-647.5
الوصف: Introduction: Measurement of alloantibody titer to a red cell antigen (ABO titers) is an integral part of management of ABO incompatible kidney transplants (ABOiKT). Material and Methods: There are different methods of titer estimation. Alloantibody detection by tube titration and Gel agglutination columns are accepted methodologies. It is essential to find the difference in titers between the two methods so as to set the 'cut-off' titer accordingly, depending upon the method used. Results: We did a prospective observational study to compare and correlate the ABO titers using these two different techniques – conventional tube technique (CTT) and the newer column agglutination technique (CAT). A total of 67 samples were processed in parallel for anti-A/B antibodies by both tube dilution and column agglutination methods. The mean titer by conventional tube method was 38.5 + 96.6 and by the column agglutination test was 96.4 + 225. The samples correlated well with Spearman rho correlation coefficient of 0.94 (P = 0.01). Conclusion: The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column agglutination results being approximately two and half fold higher (one more dilution) than that of tube method.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0973-6247
1998-3565
Relation: http://www.ajts.org/article.asp?issn=0973-6247;year=2017;volume=11;issue=2;spage=131;epage=134;aulast=Bhangale; https://doaj.org/toc/0973-6247; https://doaj.org/toc/1998-3565
DOI: 10.4103/0973-6247.214343
URL الوصول: https://doaj.org/article/4667b8b30fc9457e803cf86cb2055df9
رقم الأكسشن: edsdoj.4667b8b30fc9457e803cf86cb2055df9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09736247
19983565
DOI:10.4103/0973-6247.214343