Cuffless Blood Pressure Estimation Based on Monte Carlo Simulation Using Photoplethysmography Signals

التفاصيل البيبلوغرافية
العنوان: Cuffless Blood Pressure Estimation Based on Monte Carlo Simulation Using Photoplethysmography Signals
المؤلفون: Chowdhury Azimul Haque, Tae-Ho Kwon, Ki-Doo Kim
المصدر: Sensors, Vol 22, Iss 3, p 1175 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Chemical technology
مصطلحات موضوعية: blood pressure, cuffless, Monte Carlo simulation, photoplethysmography, machine learning, Chemical technology, TP1-1185
الوصف: Blood pressure measurements are one of the most routinely performed medical tests globally. Blood pressure is an important metric since it provides information that can be used to diagnose several vascular diseases. Conventional blood pressure measurement systems use cuff-based devices to measure the blood pressure, which may be uncomfortable and sometimes burdensome to the subjects. Therefore, in this study, we propose a cuffless blood pressure estimation model based on Monte Carlo simulation (MCS). We propose a heterogeneous finger model for the MCS at wavelengths of 905 nm and 940 nm. After recording the photon intensities from the MCS over a certain range of blood pressure values, the actual photoplethysmography (PPG) signals were used to estimate blood pressure. We used both publicly available and self-made datasets to evaluate the performance of the proposed model. In case of the publicly available dataset for transmission-type MCS, the mean absolute errors are 3.32 ± 6.03 mmHg for systolic blood pressure (SBP), 2.02 ± 2.64 mmHg for diastolic blood pressure (DBP), and 1.76 ± 2.8 mmHg for mean arterial pressure (MAP). The self-made dataset is used for both transmission- and reflection-type MCSs; its mean absolute errors are 2.54 ± 4.24 mmHg for SBP, 1.49 ± 2.82 mmHg for DBP, and 1.51 ± 2.41 mmHg for MAP in the transmission-type case as well as 3.35 ± 5.06 mmHg for SBP, 2.07 ± 2.83 mmHg for DBP, and 2.12 ± 2.83 mmHg for MAP in the reflection-type case. The estimated results of the SBP and DBP satisfy the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards and are within Grade A according to the British Hypertension Society (BHS) standards. These results show that the proposed model is efficient for estimating blood pressures using fingertip PPG signals.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1424-8220
Relation: https://www.mdpi.com/1424-8220/22/3/1175; https://doaj.org/toc/1424-8220
DOI: 10.3390/s22031175
URL الوصول: https://doaj.org/article/d4c189910e0b44208775d2c4a96f74ed
رقم الأكسشن: edsdoj.4c189910e0b44208775d2c4a96f74ed
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14248220
DOI:10.3390/s22031175