دورية أكاديمية

Electrochemical DNA Sensor for Valrubicin Detection Based on Poly(Azure C) Films Deposited from Deep Eutectic Solvent

التفاصيل البيبلوغرافية
العنوان: Electrochemical DNA Sensor for Valrubicin Detection Based on Poly(Azure C) Films Deposited from Deep Eutectic Solvent
المؤلفون: Anna Porfireva, Ekaterina Begisheva, Vladimir Evtugyn, Gennady Evtugyn
المصدر: Biosensors, Vol 13, Iss 10, p 931 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Biotechnology
مصطلحات موضوعية: deep eutectic solvent, electropolymerization, Azure C, electrochemical sensor, DNA sensor, valrubicin determination, Biotechnology, TP248.13-248.65
الوصف: A novel electrochemical DNA sensor was developed for the detection of the anthracycline drug, valrubicin, on the base of poly(Azure C) electropolymerized from the deep eutectic solvent reline and covered with adsorbed DNA from calf thymus. Biosensor assembling was performed by multiple scanning of the potential in one drop (100 µL) of the dye dissolved in reline and placed on the surface of a screen-printed carbon electrode. Stabilization of the coating was achieved by its polarization in the phosphate buffer. The electrochemical characteristics of the electron transfer were determined and compared with a similar coating obtained from phosphate buffer. The use of deep eutectic solvent made it possible to increase the monomer concentration and avoid using organic solvents on the stage of electrode modification. After the contact of the DNA sensor with valrubicin, two signals related to the intrinsic redox activity of the coating and the drug redox conversion were found on voltammogram. Their synchronous changes with the analyte concentration increased the reliability of the detection. In the square-wave mode, the DNA sensor made it possible to determine from 3 µM to 1 mM (limit of detection, 1 µM) in optimal conditions. The DNA sensor was successfully tested in the voltammetric determination of valrubicin in spiked artificial urine, Ringer-Locke solution mimicking plasma electrolytes and biological samples (urine and saliva) with a recovery of 90–110%. After further testing on clinical samples, it can find application in the pharmacokinetics studies and screening of new drugs’ interaction with DNA.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-6374
Relation: https://www.mdpi.com/2079-6374/13/10/931; https://doaj.org/toc/2079-6374
DOI: 10.3390/bios13100931
URL الوصول: https://doaj.org/article/4c32516022a841d9b44dff563022dba4
رقم الأكسشن: edsdoj.4c32516022a841d9b44dff563022dba4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20796374
DOI:10.3390/bios13100931