دورية أكاديمية

The Conometric Connection for the Implant-Supported Fixed Prosthesis: A Narrative Review

التفاصيل البيبلوغرافية
العنوان: The Conometric Connection for the Implant-Supported Fixed Prosthesis: A Narrative Review
المؤلفون: Saturnino Marco Lupi, Claudia Todaro, Dario De Martis, Paola Blasi, Ruggero Rodriguez y Baena, Stefano Storelli
المصدر: Prosthesis, Vol 4, Iss 3, Pp 458-467 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine
مصطلحات موضوعية: implant-supported dental prosthesis, fixed partial denture, conometric connection, dental implant abutment design, Medicine
الوصف: Aim: The conometric concept was proposed as a possible connection between the abutment and the prosthetic coping. This research aimed to review the features and possible clinical uses of this connection in an implant-supported fixed prosthesis. Methods: An electronic search was conducted on an online database for the topic in object; articles published in international literature were considered and the research gave 17 results, and 6 parameters were analyzed. Results: This connection eliminated the possibility of cement residues in the subgingival region, reducing the risk of inflammation of peri-implant soft and hard tissues; not having to remove the cement residues, it is possible to place the margins in more apical portions, improving the aesthetics outcomes of the rehabilitations. It is also known that the retention by means of a screw causes a weakening of the restoration. The retentive force is adequate for fixed rehabilitation even after a high number of insertion–disengagement cycles; in vitro studies have also shown a high bacterial sealing. Implant rehabilitation using preformed components, such as conometric hoods, is helpful for CAD/CAM, so a digital workflow is possible. Several types of prosthesis were presented, all of which demonstrated adequate clinical performance in the follow-up observation. Conclusions: This type of connection seems to be suitable to support fixed implant rehabilitations, but long-term clinical studies are needed to validate this system.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2673-1592
Relation: https://www.mdpi.com/2673-1592/4/3/37; https://doaj.org/toc/2673-1592
DOI: 10.3390/prosthesis4030037
URL الوصول: https://doaj.org/article/4cac35b3f219422d9616502ff756ebed
رقم الأكسشن: edsdoj.4cac35b3f219422d9616502ff756ebed
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26731592
DOI:10.3390/prosthesis4030037